The information contained here are property of DIGITAX Automotive Electronics Italy, and extremely confidential. Any disclosure, copying, distribution to third
party is strictly prohibited.
30
Programming Parameters
(Questions could be locked depending on some Country specific settings)
Here follows the complete list of F2 PLUS tariff parameters. They are 429 questions to the user.
Param.
Number
Functions
Param.
Value
1
Index fo displayed tariff
This is the number or letter to be displayed on the digit on the left hand-side of the secondary (small) display.
The display can show one of the following numbers or letters either in normal mode or in blinking mode (add 16 to the chosen value):
DISPLAY
"0"
"1"
"2"
"3"
"4"
"5"
"6"
"7"
"8"
"9"
"A"
"B"
"C"
"D"
"E"
"F"
NORMAL
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
BLINKING
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
Using the value 35 the display will not be used anymore for the tariff-index, but becomes available for other purposes. So, the secondary display becomes one of 5 digits
instead of 1 digit plus 4 digits.
TARIFF PARAMETERS
2
Distance of first unit:
the distance that corresponds with the first unit of the fare.
If Q205=No, the distance is given in meters or yards (see Q272) with one decimal digit. The allowed value goes from 0.1 (min) to 6553.5 (max).
If Q205=Yes, the distance is given with two decimal digits, and the allowed value goes from 0.01 (min) to 655.35 (max)
0.1 - 6553.5
3
Distance of second unit:
the distance that corresponds with the second unit of the fare.
If the second unit distance is the same as the first unit distance then the second unit distance does not need to be given. Automatically the first unit distance will be
used. The parameter value unit of measure, resolution and range follow the same rules of Q2
0.1 - 6553.5
4
Distance of following units:
the distance that corresponds with the third and higher units of the fare.
If the third and higher unit distance is the same as the second unit distance then the third and higher unit distance does not need to be given. Automatically the second
unit distance will be used. The parameter value unit of measure, resolution and range follow the same rules of Q2.
0.1 - 6553.5
5
Waiting-time of first unit:
the waiting-time that corresponds with the first unit of the fare.
If Q206=No, time is given in seconds with an accuracy of 0.1 sec. The allowed value goes from 0.1 s (min) to 6553.5 s (max).
If Q206=Yes, time is given with two decimal digits, and the allowed value goes from 0.01 s (min) to 655.35 s (max)
0.1 - 6553.5
seconds
6
Waiting-time of second unit:
the waiting-time that corresponds with the second unit of the fare.
If the second unit waiting-time is the same as the first unit waiting-time then the second unit waiting-time does not need to be given. Automatically the first unit waiting-
time will be used. The waiting-time is given in seconds with an accuracy of 0.1 sec.
The parameter value unit of measure, resolution and range follow the same rules of Q5
0.1 - 6553.5
seconds
7
Waiting-time of following units:
the waiting-time that corresponds with the third and higher units of the fare.
If the third and higher unit waiting-time is the same as the second unit waiting-time then the third and higher unit waiting-time does not need to be given. Automatically
the second unit waiting-time will be used.
The parameter value unit of measure, resolution and range follow the same rules of Q5
0.1 - 6553.5
seconds
8
Cost of first unit:
the cost that corresponds with the first unit of the fare. The cost is given in the local currency with an accuracy of 1. The allowed value goes from 0
(min) to 65535 (max). See Q.273 and Q.274 for adding a fixed decimal point.
0 - 65535
9
Cost of second unit:
the cost that corresponds with the second unit of the fare. If the second unit cost is the same as the first unit cost then the second unit cost does
not need to be given. Automatically the first unit cost will be used. The cost is given in the local currency with an accuracy of 1.
The allowed value goes from 0 (min) to 65535 (max). See Q.273 and Q.274 for adding a fixed decimal point.
0 - 65535
10
Cost of following units:
the cost that corresponds with the third and higher units of the fare. If the third and higher unit cost is the same as the second unit cost then the
third and higher unit cost does not need to be given. Automatically the second unit cost will be used. The cost is given in the local currency with an accuracy of 1. The
allowed value goes from 0 (min) to 65535 (max). See Q.273 and Q.274 for adding a fixed decimal point.
0 - 65535
11
Cost of fare-start (Initial Amount):
the initial cost that should be displayed at the beginning of a new fare. The cost is given in local currency units with an accuracy of
1. The allowed value goes from 0 (min) to 65535 (max). See Q.273 and Q.274 for adding a fixed decimal point.
0 - 65535
12
Cost of fare-minimum:
the minimum cost that should be displayed at the end of a fare in stopped position. The cost is given in local currency units with an accuracy of
1. The allowed value goes from 0 (min) to 65535 (max). See Q.273 and Q.274 for adding a fixed decimal point.
0 - 65535
13
Number of next block (absolute) with K1:
determines the number of the next tariff-block to be used when key K1 is pressed in Hired Position. The allowed value
goes from 0 (min) to 62 (max).
0 =Function disabled 1 to 62 = Block Number
0 - 62