background image

 

The information contained here are property of DIGITAX Automotive Electronics Italy, and extremely confidential. Any disclosure, copying, distribution to third party 
is strictly prohibited.

 

27 

The" ProgDate" 

 

“Progdate” is a kind of taximeter programming based on time events. This means that is possible to define a period of time 
during which a particular action is performed by the taximeter.  

The F2 Plus meter can be programmed with up to 50 Progdate records, every one with different activation times or action to 
be performed. 

 

The activation date of every record can be one of the following: 

from a start date to an end date 

a specific date of every year 

a specific day of every month 

some specific days of every week 

 

It is also possible to specify a time period during the activation days, defined by a start time and an end time (for example 
from 12.00 to 15.00 to identify the peak hour). 

 

When the Progdate is activated, a programmed action is performed by the meter. Some are pre-defined, with fixed meaning, 
some other are referred to the F2 PLUS programming questions. These are the possible actions codes, with their meaning: 

 

1 = Night Time 

2 = Holiday Time 

3 = actions identified by Question 63 to Question 73 of the meter programming. 

4 = actions identified by Question 74 to Question 84 of the meter programming. 

15 = Winter Time  

16 = Dimmer Time 

30 = Start new tariff (with base 30) 

31 = Start new tariff (with base 15) 

 

 

Actions related to the programming Questions can be an absolute or relative block jump, a cost percentage or delta difference 
in the costs, or other similar actions. 

 

A new tariff can be programmed in advance, and activated at a specified date and time using the “Progdate” feature of F2 
Plus.  

 

Please refer to the F2 PLUS manual for a detailed explanation of the effects of every specific one. 

 
 
 
 
 
 
 
 
 

 

Содержание F2 PLUS

Страница 1: ...Technical Manual Installation and Programming V 1 0 11 06 2020...

Страница 2: ...The information contained here are property of DIGITAX Automotive Electronics Italy and extremely confidential Any disclosure copying distribution to third party is strictly prohibited 2...

Страница 3: ...meter 13 Taximeter Display 14 Display Composition and Inscription 14 Time Syncro 15 For Hire Stopped Hired 16 The Operative Mode 16 K Constant 16 Car Odometer Transmission Ratio 17 Time and Date Setti...

Страница 4: ...gned to be easy to use while remaining very powerful This manual is conceived to be user friendly more graphical and easy to understand In the first section are described the electrical connections th...

Страница 5: ...ANSDUCER GREY F VIOLET G GREEN H YELLOW J Max 3 watts Max 25 watts WHITE Fuse 2 A PASSENGER TOOL Warning The taximeter is not provided with his own set of fuses You must install them by yourself follo...

Страница 6: ...1 s unit or 0 01 s unit Range of distance tariff 0 1 m unit to 6553 5 m unit or 0 01 m unit to 655 35 m unit Resolution of distance tariff 0 1 m unit or 0 01 m unit Odometer Transducer Input input ra...

Страница 7: ...A F 12 VOLTS POWER OUTPUT LIGHT 1 Max 1 A G 12 VOLTS POWER OUTPUT LIGHT 2 Max 1 A H 12 VOLTS POWER OUTPUT LIGHT 3 Max 1 A J 12 VOLTS POWER OUTPUT LIGHT 4 Max 1 A K INPUT BATTERY 12 VOLTS PERIPHERICAL...

Страница 8: ...y confidential Any disclosure copying distribution to third party is strictly prohibited 8 How to Fix the Taximeter Fixing Plate Screw 3MA 7x29 5 mmm Front View Fixed the bracket Locking direction Das...

Страница 9: ...n the 4 screws A and insert the internal wire Do not tight the 4 screws A Attention when you insert the internal wire the dummy shaft must come out and be disposed off Shaft A Re assemble the transmis...

Страница 10: ...ential Any disclosure copying distribution to third party is strictly prohibited 10 upside view Side view Front view PINK VIOLET TIME BLOCK INPUT FARE INCREMENT PULSE OUTPUT YELLOW DISTANCE PULSES OUT...

Страница 11: ...seal is broken and the taximeter is again initialized MAIN DISPLAY PRINTED REPORT DESCRIPTION EVENTS K CONST Constant K calibration Autotest A DEFAULT ESeal Auto Default due to structure corruption A...

Страница 12: ...e Electronics Italy and extremely confidential Any disclosure copying distribution to third party is strictly prohibited 12 E Seal Electronic Sealing 2nd Section It is possible to toggle between 1st s...

Страница 13: ...n to third party is strictly prohibited 13 How to Seal the Taximeter Regular Way of Sealing the Taximeter Sealing Screw Sealing Bush Sealing Wire Sealing Lead Disk Sealed to the bracket Sealed to the...

Страница 14: ...ex 3 Fare Display 4 Status For Hire Hired Stopped 5 Secondary Display 6 Passenger detection status when it s blinking 7 Description extras time 8 Metrological Inscriptions Plate 9 Serial Number 10 Fac...

Страница 15: ...f at least 7 days are passed from last synchronization or clock change The Time Synchro works only if the manual time setting is disabled Q269 Yes For example when the taximeter clock is between 11 58...

Страница 16: ...the Hired position by pressing OP button The Taxi roof sign turns off and the taximeter starts the fare calculation by distance or time The left display shows the tariff value The right one shows in t...

Страница 17: ...he taximeter programming cover Select For Hire position Insert the Black Programming Key in its slot Press K2 and K3 buttons at the same time The left display shows Attest for a few seconds Now the Fo...

Страница 18: ...IRE and STOPPED starts blinking The big display shows in the left digits the day number and in right digits the month The small display shows the time in HH MM format To set the Day number press K1 bu...

Страница 19: ...check sum manually IE by Inspectors in every moment but only when the meter is in FOR HIRE mode by pressing together K1 K4 to verify that the meter is programmed with the right tariff The CRC16 Check...

Страница 20: ...antity integer 3 Total Amount all including currency 4 Fare Amount currency 5 Extras Amount currency 6 Discounts Amount currency 7 VAT Amount currency 8 Amount per km or mile currency 9 Total Distance...

Страница 21: ...dvanced Functions enabled by the Black Programming Key Some specific actions are allowed only when the taximeter is un sealed and the Black Programming key is inserted Loc Block Action w key inserted...

Страница 22: ...ettings Select For Hire position Press K1 and K2 at the same time to enter in the Statistical Reading mode The big display will show Statis for a few seconds Now the sign FOR HIRE starts blinking Reac...

Страница 23: ...ble to move from Block 1 to Block 2 and change the Initial value by depressing K1 button Power on the taximeter By default all the parameters programmed in Block 0 get loaded in the Working Block Pres...

Страница 24: ...e them in a so called Working Block this is the one that makes the final amount calculation The blocks chain starts with the Block 0 It s the first Block that the taximeter loads when it s being start...

Страница 25: ...ent system And the values showed for prices will be of course in the local currency These 7 values are shown in the following parameters in order of appearance for each programmed Block the procedure...

Страница 26: ...he menu selection 2 Select TAR SH by pressing K2 3 Confirm by K4 the Tariff Show viewer 4 To go to the next programmed value press K4 5 To go to the previous programmed value press K3 Every time K4 is...

Страница 27: ...start time and an end time for example from 12 00 to 15 00 to identify the peak hour When the Progdate is activated a programmed action is performed by the meter Some are pre defined with fixed meanin...

Страница 28: ...es might be defined for special customized functions RECEIPT COPY press K4 to print a duplicate of last trip receipt E SEAL press K4 to enter E Seal menu please refer to its chapter TAR SHOW press K4...

Страница 29: ...imeter to the memory key Upload will appear on main display NOTE only tariff settings already into key will be updated c enables manual programming procedures AutoTest Tariff Programming Fares Extras...

Страница 30: ...at corresponds with the second unit of the fare If the second unit waiting time is the same as the first unit waiting time then the second unit waiting time does not need to be given Automatically the...

Страница 31: ...is is the percentage or Fixed Cost of extra charge number 3 in Stopped that can be applied with key K2 In order to establish whether this value has to be interpreted as a percentage or as a cost consu...

Страница 32: ...centage in night time with K1 Passing from Hired to Stopped in night time should the parameter of Q 42 be inserted as a percentage pressing key K1 No Yes HOLIDAY Prog Date N 2 51 Day of week considere...

Страница 33: ...62 max 0 62 76 Percentage or cost in Prog Date 4 This is the percentage or the cost that will be applied during the date and time as programmed in Prog Date 4 The interpretation as a percentage or as...

Страница 34: ...es 115 Insert as percentage in Prog Date 7 NOT USED for F2 Plus No Yes 116 Insert as fixed cost in Prog Date 7 NOT USED for F2 Plus No Yes 117 Insert as percentage in Prog Date 7 with K1 NOT USED for...

Страница 35: ...former block number is used again 0 62 141 Block offset at event n 1 This is the block offset relative to be used when the event occurred that has been programmed in Q 139 The relative block offset is...

Страница 36: ...ock to change to is to be programmed in Q 173 0 65535 173 Block Number abs at event n 4 this is the block number absolute to be used when the event occurred that has been programmed in Q 172 The allow...

Страница 37: ...h see Q272 If this question is set to 0 default the cross speed is automatically calculated based on Q 2 3 4 and Q 5 6 7 A fixed cross speed can be obtained by programming a value between 1 and 191 If...

Страница 38: ...OFF or 1 Yes ON No Yes 231 Block number for light n 1 ON this is the number of the tariff block where light number 1 should be ON The allowed value goes from 0 min to 62 max 0 64 232 Prog Date number...

Страница 39: ...mmed Q338 Q339 Q340 No Yes 261 The Light n 4 must go ON if the shift is Open If Yes then the Light n 4 will go ON in case the shift is OPEN No Yes 262 Available for future extensions No Yes 263 Light...

Страница 40: ...which the fare cost will be discarded and the taximeter will restart in Stopped The time is given in seconds with an accuracy of 1 second The allowed value goes from 0 min to 255 max 0 255 seconds 287...

Страница 41: ...d 0 open 1 closed 313 Black fare registr or autom in Hired After the distance programmed in Q 310 should be activated either the registration in memory of the black fare with a passenger aboard in Sto...

Страница 42: ...allowed answer is either 0 No disabled or 1 Yes enabled No Yes 341 Enable programming forfait with front keys If yes then with the taximeter in Hired and pressing the keys K1 K4 together the forfait a...

Страница 43: ...length for COM 1 what is the maximum length of a data packet of COM 1 The packet length is given in byte with an accuracy of 1 byte The allowed value goes from 1 min to 512 max 0 512 393 Baudrate for...

Страница 44: ...e vehicle is calibrated The distance is given in metres with an accuracy of 1 metre The allowed value goes from 0 min to 9999 max 0 9999 meters 412 Statistical memories chosen to be print ed out value...

Страница 45: ...The information contained here are property of DIGITAX Automotive Electronics Italy and extremely confidential Any disclosure copying distribution to third party is strictly prohibited 45...

Страница 46: ...info digitax com Digitax UK Digitax Mauritius Digitax Deutschland Smokehouse 31 Tanners Bank North Shields Tyne Wear NE 30 1 JH ENGLAND P O box 775 Bel Village MAURITIUS Taxitech Handelsges mbh Somme...

Отзывы: