13-2
Data format
The data field format is selected using parameter
b51
.
7-bit plus parity (bit 51 = 0)
One start-bit
Seven data bits
One even parity bit
One stop bit
8-bit, no parity (bit 51 = 1)
One start bit
Eight data bits
One stop bit
13.5 Message
structure
Serial messages consist of the following:
Control characters
Serial address code
Parameter identifier
Data field
Block checksum (
BCC
)
Control characters
If a message is initiated from a keyboard, control
characters may be entered by holding down the
CTRL
key and pressing the key shown in the table
below.
Character
Purpose
ASCII
code
(HEX)
CTRL +
key
EOT
Reset
Message begins
04
D
ENQ
Enquiry
Interrogating the Drive
05
E
STX
Start of text
02
B
ETX
End of text
03
C
ACK
Acknowledge
(go to next parameter)
06
F
BS
Backspace
(go to previous
parameter)
08
H
NAK
Negative acknowledge
(repeat same
parameter)
15
U
CR
Carriage return
0D
M
Serial address code
Each Drive on a serial link must have a unique
address. This allows the host controller to
communicate with each Drive individually. The
Drive address code is entered in Pr22, and can be
any value between 1 and 32. (Drive address 00 has a
special use, see below) Each digit of the address is
transmitted twice, so to address Drive 08, the
following must be transmitted:
Drive address
0
0
8
8
It is possible to send an instruction to all Drives on
the serial link using Drive address 00. All Drives will
listen to the an instruction, but none will
acknowledge. This can be useful for ensuring that
all Drives on a flow line get the
START
signal at the
same instant.
Parameter identifier
To address an individual parameter, the host must
send a code that relates to that parameter. There
are two types of parameter in the DigitAx:
Numerical parameters
Pr00
to
Pr99
Parameter identity
000 to 099
Bit parameters
b00
to
b99
Parameter identity
100 to 199
Data field
Data is sent as a numerical value with sign and
decimal point. The data field can consist of up to six
characters, two of which must be the sign and
decimal point. The data field can be shortened
when transmitting data to the Drive, since the
ETX
control character (see above) indicates the data is
complete. The response of the Drive, when
interrogated, will always have six data characters.
Block checksum
The block checksum character (
BCC
) is used to
check the received message has not been corrupted
during transmission. The
BCC
is a value that is
calculated from the
ASCII
codes of the characters in
the parameter identifier and data fields. The
BCC
is
calculated by using the
XOR
function, and starts
with the first character following the
STX
(ctrl B)
control character. The following example shows
how to calculate the
BCC
.
Содержание DBE1100S
Страница 3: ...User Guide DigitAx AC Servo Drive 1 4kW to 22kW Part Number 0415 0008 Issue Number 4...
Страница 8: ...DigitAx User Guide Issue code dgxu4 iv...
Страница 20: ...DigitAx User Guide Issue code dgxu4 3 8...
Страница 28: ...DigitAx User Guide Issue code dgxu4 4 8...
Страница 48: ...DigitAx User Guide Issue code dgxu4 5 20...
Страница 50: ...DigitAx User Guide Issue code dgxu4 6 2...
Страница 54: ...DigitAx User Guide Issue code dgxu4 8 2...