DigitAx User Guide
Issue code: dgxu4
10-10
Use the following procedure to select Stop-and-hold
mode:
1.
Configure terminal B6 as follows for the
voltage sense of the Stop signal:
b88 setting
Stop signal
0
+24V
1
0V
2.
Set
b22
at 1 for stopping with ramps.
3.
Set
Pr11
and
Pr12
for deceleration rate in
milliseconds per 1000
RPM
.
Limit-switch stop-and-hold
When a limit-switch is triggered, the Drive inhibits
rotation in that direction, and stops the motor. The
motor can be stopped without deceleration ramp
(stopping under current limit), or ramps can be
included to make the stop smoother. When the
motor has stopped, the Drive will keep the motor in
torque to prevent the mechanical system from
moving past the end-stop.
Ramps are selected by setting
b23
at 1. When the
limit-switch is activated, the Drive decelerates the
motor at the rate set in
Pr11
or
Pr12
. Selection of
ramps for the limit-switch stop-and-hold mode is
independent of whether or not ramps are selected
to act on the speed reference.
Use the following proceudre to configure the limit-
switch stop functions:
1.
Set
b16
at 1.
2.
Set
b23
at 1 to select ramps.
3.
Apply the limit-switch signals as follows:
Limit-
switch
Terminal
B4
B5
Forward
X
0
Reverse
0
X
0 = logic 0 = 0V = Stop
(X = don’t care)
Stop, hold and orientate
See
Spindle orientation
earlier in this chapter.
10.12 Quick reference
Note
A maximum speed limit is programmable in
Pr58. The Drive is disabled if the motor
speed exceeds the programmed value.
Speed control
Make the following settings:
Type of speed reference
b6
b14
b15
b17
Analog
0
1
X
0
Digital
0
X
X
1
Frequency
0
0
0
0
Ramps can be applied to all types of speed reference
by setting
b7
at 1.
Torque control
Make the following settings:
Type of torque
reference
b6
b8
b11
b56
Analog
1
0
0
1
Digital
1
1
0
1
Speed control with external
torque limit
0
X
1
0
Position control
Make the following settings:
Type of position
Reference
b14
b15
b16
b17
Pulse
0
1
1
0
Digital
0
1
1
0
Fixed increment
0
1
0
0
Содержание DBE1100S
Страница 3: ...User Guide DigitAx AC Servo Drive 1 4kW to 22kW Part Number 0415 0008 Issue Number 4...
Страница 8: ...DigitAx User Guide Issue code dgxu4 iv...
Страница 20: ...DigitAx User Guide Issue code dgxu4 3 8...
Страница 28: ...DigitAx User Guide Issue code dgxu4 4 8...
Страница 48: ...DigitAx User Guide Issue code dgxu4 5 20...
Страница 50: ...DigitAx User Guide Issue code dgxu4 6 2...
Страница 54: ...DigitAx User Guide Issue code dgxu4 8 2...
Страница 56: ...DigitAx User Guide Issue code dgxu4 9 2...
Страница 94: ...DigitAx User Guide Issue code dgxu4 13 6...