DigitAx User Guide
Issue code: dgxu4
11-2
Pr11
Deceleration ramp — forward
R–W
1 to 3000
ms
Def
.
val.
200
Res.
1
Slope in milliseconds per 1000
RPM.
Pr12
Deceleration ramp — reverse
R–W
1 to 3000
ms
Def
.
val.
200
Res.
1
Slope in milliseconds per 1000
RPM.
Pr13
Proportional gain
R–W
0 to 255
Def
.
val.
30
Res.
1
Pr14
Derivative gain
R–W
0 to 128
Def
.
val.
30
Res.
1
Pr15
Integral gain
R–W
0 to 255
Def
.
val.
30
Res.
1
Pr16
Resolver Phasing
R–W
0 to 2047
Def
.
val.
0
Res.
1
Value of the resolver phase correction
.
Refer to
Resolver Phasing
in
Chapter 10 Getting Started.
Pr17
Digital reference
RO
0 to 3
Def
.
val.
Res.
Indicates the reference selected in
Pr21
Pr18
Digital input configuration
(terminals B4 and B5)
RO
0 to 3
Def
.
val.
Res.
Indicates the signals on terminals B4 and B5, as
follows:
0V or open-circuit = 0
+24V = 1
The indications are as follows:
Terminal
Pr18
B4
B5
0
0
0
0
1
1
1
0
2
1
1
3
Pr19
Digital reference scan time
R–W
0.1 to 600.0
s
Def
.
val.
10.0s
Res.
0.1
Pr20
Digital reference selector /
Number of offset pulses
R–W
(See below)
Def
.
val.
0
Res.
1
Normal control
Range: 0 to 3
Select the required digital reference.
Position control
Range: 0 to 255
Resolution: 1
Enter the required number of position counts in the
position buffer every 5 ms.
Pr21
Digital reference selector
enable
R–W
0, 1 or 2
Def
.
val.
0
Res.
1
When
Pr21
= 0,
Pr20
is used as digital reference
selector.
When
Pr21
= 1, sequential selector
Pr19
is enabled.
When
Pr21
= 2 and
b16
= 0, digital inputs are
enabled.
Pr22
Drive address
R–W
1 to 32
Def
.
val.
1
Res.
1
A Drive address is required when serial
communications are used
.
Each Drive on a serial
communications link must have an individual
address.
Pr23
Baud rate
R–W
300 to 19200
Def
.
val.
9600
Res.
This parameter can be set only at the control
keypad, not by using serial communications
.
Available values are as follows:
300, 600 1200, 2400, 4800, 9600, 19200
The host computer must be set at the same Baud
rate as the Drive.
Содержание DBE1100S
Страница 3: ...User Guide DigitAx AC Servo Drive 1 4kW to 22kW Part Number 0415 0008 Issue Number 4...
Страница 8: ...DigitAx User Guide Issue code dgxu4 iv...
Страница 20: ...DigitAx User Guide Issue code dgxu4 3 8...
Страница 28: ...DigitAx User Guide Issue code dgxu4 4 8...
Страница 48: ...DigitAx User Guide Issue code dgxu4 5 20...
Страница 50: ...DigitAx User Guide Issue code dgxu4 6 2...
Страница 54: ...DigitAx User Guide Issue code dgxu4 8 2...
Страница 56: ...DigitAx User Guide Issue code dgxu4 9 2...
Страница 94: ...DigitAx User Guide Issue code dgxu4 13 6...