DigitAx User Guide
Issue code: dgxu4
11-3
Pr24
Digital run reference
RO
±
6000
RPM
Def
.
val.
Res.
1
Indicates the value of the selected digital reference
in
RPM
at the start of the speed loop.
Pr25
Security code
R–W
1 to 9999
Def
.
val.
0
Res.
1
Security gives write protection to parameters
.
Refer to Setting up a security code in Chapter 9.
Pr26
Drive model code
RO
(See below)
Def
.
val.
Res.
The model number is coded as follows:
0
DBE140
1
DBE220
2
DBE420
3
DBE600
7
DBE750
11
DBE1100S
12
DBE1500, DBE2200
Pr27
Shaft orientation function in
resolver steps
R–W
0 to 2047
steps
Def
.
val.
0
Res.
1
When
b53
= 1,
Pr27
determines the shaft
orientation as directed by either
b18
or the input at
terminal
B6
.
See
Pr37
,
Pr53
,
Pr54
,
Pr83
,
b41
.
Pr30
Digital output selector 1
R–W
0 to 8
Def
.
val.
0
Res.
1
Selects the source parameter for terminal B7.
Value of Pr30
Parameter selected
0
b89
I
2
t alarm
1
b91
Temperature pre-alarm
2
b84
Current limit alarm
3
b38
Present direction
4
b41
Motor stopped
5
b42
At Speed
6
b48
Speed loop saturation
7
b4
Drive enable status
8
b95
Braking resistor overload
Pr31
Digital output selector 0
R–W
0 to 8
Def
.
val.
1
Res.
1
Selects the source parameter for terminal B8.
Value of Pr31
Parameter selected
0
b89
I
2
t alarm
1
b91
Temperature pre-alarm
2
b84
Current limit alarm
3
b38
Present direction
4
b41
Motor stopped
5
b42
At Speed
6
b48
Speed loop saturation
7
b4
Drive enable status
8
b95
Braking resistor overload
Pr37
Orientation (position) loop gain
R–W
0 to 50
Def
.
val.
12
Res.
1
When the orientation function is selected (Normal
stop while
b53
= 1), the Drive automatically sets the
orientation loop gain.
Pr39
Analog current limit input
RO
-100 to +100
%
Def
.
val.
Res.
1
Indicates the value of the reference voltage on
analog input terminal B1
.
–100% to +100% represents –10V to +10V.
Pr40
Clamped current demand
RO
–100 to +100
%
Def
.
val.
Res.
1
Indicates the value of the current after limiting
by
Pr41
.
Pr41
Current limitation value
RO
0 to +100
%
Def
.
val.
Res.
1
Indicates the lowest value set in the following
parameters:
I
2
t limit (
Pr43
)
Analog limit (rectified) (
Pr39
) when
b11
= 1
Digital limit
Pr42
0 is shown when the Drive is disabled.
Содержание DBE1100S
Страница 3: ...User Guide DigitAx AC Servo Drive 1 4kW to 22kW Part Number 0415 0008 Issue Number 4...
Страница 8: ...DigitAx User Guide Issue code dgxu4 iv...
Страница 20: ...DigitAx User Guide Issue code dgxu4 3 8...
Страница 28: ...DigitAx User Guide Issue code dgxu4 4 8...
Страница 48: ...DigitAx User Guide Issue code dgxu4 5 20...
Страница 50: ...DigitAx User Guide Issue code dgxu4 6 2...
Страница 54: ...DigitAx User Guide Issue code dgxu4 8 2...
Страница 56: ...DigitAx User Guide Issue code dgxu4 9 2...
Страница 94: ...DigitAx User Guide Issue code dgxu4 13 6...