b38
Direction of motor rotation
RO
Def
.
val.
Res.
Indicates the direction of rotation when seen at the
drive shaft end of the motor.
b38
= 0 indicates the motor is rotating in th e
reverse (counterclockwise) direction.
b38
= 1, indicates the motor is rotating in the
forward (clockwise) direction.
b41
Zero speed or shaft orientation
status
RO
Def
.
val.
Res.
b53
= 0,
b41
= 0 indicates motor not at zero speed.
b53
= 1,
b41
= 0 indicates shaft not orientated.
b53
= 0,
b41
= 1 indicates motor at zero speed.
b53
= 1,
b41
= 1 indicates shaft is oriented
.
See
Pr27
.
When the Drive is being used for position control,
b41
indicates
In Position
.
b42
At-speed status
RO
Def
.
val.
Res.
b42
= 0 indicates motor not at speed — motor
speed is outside the range defined by
Pr56
and
Pr57
.
b42
= 1 indicates motor
At speed
— motor speed
is within the range defined by
Pr56
and
Pr57
.
Refer also to
Pr56
,
Pr57
and
b96
.
b48
Speed loop saturation status
RO
Def
.
val.
Res.
Indicates whether the speed loop is operating
linearly or is in saturation.
b48
= 0 indicates the speed loop is in linear
operation.
b48
= 1 indicates the speed loop is saturated.
b49
Resolver phasing
R–W
0 or 1
Def
.
val.
0
Res.
When
b49
is set at 0, resolver phasing is inactive.
When
b49
is set at 1, resolver phasing is enabled.
Warning
Change the value of b49 only
when the Drive is disabled by
setting b2 at 0, and the
motor is stopped
b50
Display return function
R–W
0 or 1
Def
.
val.
0
Res.
When
b50
is set at 0, the control keypad display
returns to
rdY
or the speed value after 8 seconds
without a key stroke.
When
b50
is set at 1, the display continues to show
the value of the last parameter to have been
selected.
b51
Serial link data format
R–W
0 or 1
Def
.
val.
0
Res.
When
b51
is set at 0, 8 data bits with no parity is
selected.
When
b51
is set at 1, 7 data bits with even parity is
selected.
Note
This parameter can be adjusted only at the
keypad, not by using serial communications.
b52
Serial link mode
R–W
0 or 1
Def
.
val.
0
Res.
When
b52
is set at 0,
ANSI
standard is selected.
When
b52
is set at 1, Terminal mode is selected.
b53
Digital stop mode selector
R–W
0 or 1
Def
.
val.
0
Res.
When
b53
is set at 0, stop and hold is selected.
When
b53
is set at 1, stop, orientate, and hold is
selected.
See
Pr27
.
b55
External Trip Alarm
RO
Def
.
val.
Res.
b55
= 0 indicates no external trip.
b55
= 1 indicates external trip active.
Содержание DBE1100S
Страница 3: ...User Guide DigitAx AC Servo Drive 1 4kW to 22kW Part Number 0415 0008 Issue Number 4...
Страница 8: ...DigitAx User Guide Issue code dgxu4 iv...
Страница 20: ...DigitAx User Guide Issue code dgxu4 3 8...
Страница 28: ...DigitAx User Guide Issue code dgxu4 4 8...
Страница 48: ...DigitAx User Guide Issue code dgxu4 5 20...
Страница 50: ...DigitAx User Guide Issue code dgxu4 6 2...
Страница 54: ...DigitAx User Guide Issue code dgxu4 8 2...
Страница 56: ...DigitAx User Guide Issue code dgxu4 9 2...
Страница 94: ...DigitAx User Guide Issue code dgxu4 13 6...