DigitAx User Guide
Issue code: dgxu4
11-10
b96
At-speed relative/absolute
R–W
0 or 1
Def
.
val.
1
Res.
Defines the type of signal given by the At-speed
status parameter
b42
.
When
b96
is set at 0, absolute is selected.
When
b96
is set at 1, relative is selected.
When
b96
is set at 1 (relative) the At-speed status
held in
b42
is related to the Speed Reference input,
so that
b42
= 1 (At speed) when the motor speed is
between the two limits, as follows:
Greater than
[Speed reference]
–
Pr56
Less than
[Speed reference] +
Pr57
When
b96
is set at 0 (Absolute) the At-speed
status held in
b42
responds to the absolute values
set in
Pr56
and
Pr57
, so that
b42
= 1 (At speed)
when the motor speed speed is between the two
limits, as follows:
Greater than
Pr56
Less than
Pr57
Refer also to
Pr56
,
Pr57
and
b42
.
b99
Save RAM to EEPROM
R–W
0 or 1
Def
.
val.
0
Res.
Saves new parameter values in the
EEPROM
. The
display shows
SAVE
while parameters are being
saved
.
b99
is related to
b1
and
b5
.
When
b99
is set at 0, no saving occurs.
When
b99
is set at 1, parameters are saved.
Содержание DBE1100S
Страница 3: ...User Guide DigitAx AC Servo Drive 1 4kW to 22kW Part Number 0415 0008 Issue Number 4...
Страница 8: ...DigitAx User Guide Issue code dgxu4 iv...
Страница 20: ...DigitAx User Guide Issue code dgxu4 3 8...
Страница 28: ...DigitAx User Guide Issue code dgxu4 4 8...
Страница 48: ...DigitAx User Guide Issue code dgxu4 5 20...
Страница 50: ...DigitAx User Guide Issue code dgxu4 6 2...
Страница 54: ...DigitAx User Guide Issue code dgxu4 8 2...
Страница 56: ...DigitAx User Guide Issue code dgxu4 9 2...
Страница 94: ...DigitAx User Guide Issue code dgxu4 13 6...