Command Conventions
•
The commands are not case sensitive.
•
A command must be entered in full.
•
You can delete an incorrect command with the Backspace key before you press
Enter.
•
If you type a valid RCM command, followed by extra characters, and press
Enter, the RCM accepts the correct command and ignores the extra characters.
•
If you type an incorrect command and press Enter, the command fails with the
message:
*** ERROR - unknown command ***
alert_clr
The alert_clr command clears an alert condition within the RCM. The alert enable
condition remains active, and the RCM will again enter the alert condition if it
detects a system power failure.
RCM>alert_clr
alert_dis
The alert_dis command disables RCM dial-out. It also clears any outstanding alerts.
Dial-out remains disabled until the alert_enable command is issued. See also the
enable and disable commands.
RCM>alert_dis
alert_ena
The alert_ena command enables the RCM to automatically dial out when it detects
a power failure within the system. The RCM repeats the dial-out alert at 30-minute
intervals until the alert is cleared. Dial-out remains enabled until the alert_disable
command or the disable command is issued. See also the enable and disable
commands.
RCM>alert_ena
Содержание AlphaServer 1200
Страница 12: ......
Страница 50: ......
Страница 90: ......
Страница 127: ...Error Logs 4 37...
Страница 150: ......
Страница 174: ...6 10 Service Manual PRELIMINARY 6 5 CPU Fan Removal and Replacement Figure 6 4 Removing CPU Fan PKW 0516 97...
Страница 194: ...6 30 Service Manual PRELIMINARY 6 15 CD ROM Removal and Replacement Figure 6 14 Removing CD_ROM 1 PKW0519 97...
Страница 196: ...6 32 Service Manual PRELIMINARY 6 16 Floppy Removal and Replacement Figure 6 15 Removing Floppy 1 PKW0520 97...
Страница 204: ......
Страница 236: ......
Страница 244: ......
Страница 272: ......