Removal and Replacement
6-19
Removal
1.
Shut down the operating system and power down the system.
2.
Expose the card cage side of the system. See Section 6.3
3.
To remove the faulty option: Disconnect cables connected to the option.
Remove cables to other options that are in the way of removing the option you
are removing. Unscrew the small Phillips head screw securing the option to the
card cage. Slide it from the system.
Replacement
Reverse the steps in the Removal procedure.
Verification — DIGITAL UNIX and OpenVMS Systems
1.
Power up the system (press the Halt button if necessary to bring up the SRM
console) and run the ECU to restore EISA configuration data.
2.
Issue the show config command or show device command at the console
prompt to verify that the system sees the option you replaced.
3.
Run any diagnostic appropriate for the option you replaced.
Verification — Windows NT Systems
1.
Start AlphaBIOS Setup, select Display System Configuration, and press
Enter.
2.
Using the arrow keys, select PCI Configuration or EISA Configuration to
determine that the new option is listed.
Содержание AlphaServer 1200
Страница 12: ......
Страница 50: ......
Страница 90: ......
Страница 127: ...Error Logs 4 37...
Страница 150: ......
Страница 174: ...6 10 Service Manual PRELIMINARY 6 5 CPU Fan Removal and Replacement Figure 6 4 Removing CPU Fan PKW 0516 97...
Страница 194: ...6 30 Service Manual PRELIMINARY 6 15 CD ROM Removal and Replacement Figure 6 14 Removing CD_ROM 1 PKW0519 97...
Страница 196: ...6 32 Service Manual PRELIMINARY 6 16 Floppy Removal and Replacement Figure 6 15 Removing Floppy 1 PKW0520 97...
Страница 204: ......
Страница 236: ......
Страница 244: ......
Страница 272: ......