![Digital Electronics GP-2401 Series Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/digital-electronics/gp-2401-series/gp-2401-series_user-manual_2498452014.webp)
GP-2401/2501/2601 Series User Manual
13
Preface
UL/c-UL (CSA) Application Notes
The GP2401-TC41-24V, GP2501-LG41-24V are UL/c-UL (CSA) listed products.
(UL file No.E182139)
The GP2501-TC11
*1
, GP2501-SC11
*1
, GP2601-TC11
*1
are UL/c-UL (CSA) recog-
nized components. (UL file No.E231702)
These units conform to the following standards:
A) UL508
Industrial Control Equipment
B) UL60950
Safety Standard for Information Technology Equipment (3rd Edition,
issued December 1, 2001)
C) UL1604
Electrical Equipment for use in Class 1 & 2 - Division 2, or Class 3
Hazardous Locations.
D) CAN/CSA-C22.2, Nos. 142, and 213-M1987
Safety Standard for Information
Technology and Electrical Business Equipment
E)
CAN/CSA-C22.2 No. 1010-1
Safety Requirement for Electrical Equipment for Measurement, Control and Labo-
ratory Use
F) CAN/CSA-C22.2, No. 60950-00
Safety Standard for Information Technology
Equipment (3rd Edition, issued December 1, 2001)
G) CAN/CSA-C22.2, No. 213-M1987
Safety Standard for Information Technol-
ogy and Electrical Business Equipment
<Cautions>
• GP units must be used as a built-in component of an end-use product.
• GP units must be used indoors only.
• GP units should be installed in the front face of a metal panel.
• If this unit is installed so as to cool itself naturally, be sure to install it in a
vertical panel. Also, be sure that the GP unit is mounted at least 100 mm away
from any adjacent structures or equipment. If these requirements are not met,
the heat generated by the GP unit’s internal components may cause the unit to
fail to meet UL/c-UL standard requirements.
• Be sure to create a power ON/OFF switch for the GP on or in the end-use
product that the GP unit is built-in. Be sure to consider the current and voltage
levels when installing the switch.
• Be sure that the end-use the product uses a UL60950 approved structure.
*1
All GP units marked Revision "3" conform to UL/c-UL standard requirements.
For more information on how to determine the revision version, see
"Revision Version" (page 14).
A
B
C
D
E
F
G
GP2401-TC41-24V
3180034-01
GP2501-TC11*
1
3180021-03
GP2501-SC11*
1
3180021-04
GP2501-LG41-24V
3180045-01
GP2601-TC11*
1
3180021-05
Standards
Model
UL registered
format
Содержание GP-2401 Series
Страница 1: ...GP 2401 2501 2601 Series User Manual Digital Electronics Corporation ...
Страница 25: ...Memo ...
Страница 69: ...Memo ...
Страница 103: ...Memo ...
Страница 129: ...Memo ...
Страница 137: ...Chapter 8 Maintenance GP 2401 2501 2601 Series User Manual 8 8 Memo ...