EVO Control Panel
25
sequentially, skipping any disabled numbers and stopping once all selected
telephone numbers have been reached. If the control panel still fails to
report to a monitoring station telephone number after reaching the
Maximum Dialing Attempts (see
panel will dial the selected backup telephone number. For each section
enable or disable the options:
(default =
only option [1] enabled
)
9.8.1 Maximum Dialing Attempts*
S
ECTION
[3056]
(default =
008
) The number (001 to 255, 000 = 8 attempts) programmed
into section
[3056]
determines how many tries before proceeding to the
next number. Also refer to
* UL Note:
For UL Listed systems, the maximum dialing attempts must be set
to 5 to 10 attempts between the EVO’s two telephone lines.
9.8.2 Delay Between Dialing Attempts
S
ECTION
[3054]
(default =
020
) This delay can be set from 001 to 127 seconds.
9.8.3 Alternate Dialing Option
S
ECTION
[3037]: O
PTION
[6]
(default =
disabled
) When enabled, the control panel dials the selected
backup telephone number after every failed attempt to contact a monitoring
station telephone number. When disabled, the control panel dials the
backup telephone number after the Maximum Dialing Attempts (see
to one monitoring station telephone number fail.
9.9 Pager Delay
S
ECTION
[3057]
(default =
020
) When using the Pager Reporting Format (see
the control panel will wait for the delay period programmed into section
[3057]
before uploading the report codes to the pager. Enter any value
between 001 and 127 to determine Pager Delay in seconds.
9.10 Recent Close Delay
(default =
000
) If an alarm is generated within the programmed period after
arming the partition, the control panel will transmit the
Recent Close
report
code programmed into section
[3933]
. Enter any value between 001 and
255 to determine Recent Close Delay in seconds.
9.11 Power Failure Report Delay
S
ECTION
[3058]
(default =
030
) The control panel will delay the transmission of the
AC
Failure
report code programmed into section
[3941]
by the period
programmed into section
[3058]
. Enter any value between 001 and 255 to
determine Power Failure Report Delay in minutes.
9.12 Power Failure Restore Report Delay
S
ECTION
[3060]
(default =
030
) The control panel will delay the transmission of the
AC
Failure
Restore
report code programmed into section
[3972]
by the period
programmed into section
[3060]
. Enter any value between 001 and 255 to
determine Power Failure Restore Report Delay in minutes.
9.13 Repeat Pager Report Code Transmission
S
ECTION
[3059]
{default =
000
) This feature re-sends the report code as specified.
9.14 Auto Test Report
S
ECTION
[3037]: O
PTIONS
[3]
AND
[4]
AND
S
ECTIONS
[3040], [3041], [3042]
AND
[3043]
The control panel can transmit the test report code programmed into
section
[3902]
every hour or after a period of time.
9.15 Disarm Reporting Options
(default =
disabled)
When disabled, the control panel sends the Disarming
Report Codes (see
on page 22) every time the partition is
disarmed. When enabled, the control panel sends the Disarming Report
Codes to the monitoring station only when the partition is disarmed
following an alarm. Select the section that corresponds to the desired
partition and enable or disable option
[7]
:
9.16 Zone Restore Report Options
S
ECTION
[3037]: O
PTION
[8]
(default =
disabled
) When disabled, the control panel sends the
Zone
Alarm Restore
report codes to the monitoring station when the Bell Cut-Off
Timer elapses (see
or when the alarm is disarmed. When
Troubles and Restore Troubles:
[3080]
Special System, Arming, Disarming and Alarm Reporting:
[3081]
Access Code and Keyswitch Arming and Disarming
Partition 1:
[3127]
Partition 3:
[3327]
Partition 5:
[3527]
Partition 7:
[3727]
Partition 2:
[3227]
Partition 4:
[3427]
Partition 6:
[3627]
Partition 8:
[3827]
Zone Alarms and Alarm Restores
Partition 1:
[3128]
Partition 3:
[3328]
Partition 5:
[3528]
Partition 7:
[3728]
Partition 2:
[3228]
Partition 4:
[3428]
Partition 6:
[3628]
Partition 8:
[3828]
Tampers and Tamper Restores
Partition 1:
[3129]
Partition 3:
[3329]
Partition 5:
[3529]
Partition 7:
[3729]
Partition 2:
[3229]
Partition 4:
[3429]
Partition 6:
[3629]
Partition 8:
[3829]
Option Call:
Option Call
(select one only)
:
[1]
Telephone Number 1
[5]
Backup on Number 1
[2]
Telephone Number 2
[6]
Backup on Number 2
[3]
Telephone Number 3
[7]
Backup on Number 3
[4]
Telephone Number 4
[8]
Backup on Number 4
Partition 1:
[3109]
Partition 3:
[3309]
Partition 5:
[3509]
Partition 7:
[3709]
Partition 2:
[3209]
Partition 4:
[3409]
Partition 6:
[3609]
Partition 8:
[3809]
OFF OFF
Auto Test
Report
Period
(default)
After the number programmed (000 to 255 days,
default =
000
) in section
[3040]
, the control panel
transmits a report code at the time (00:00 to 23:59,
default =
00:00
) programmed in section
[3041]
.
OFF ON
Timed Test
Transmission
when Armed/
Disarmed
When disarmed: The control panel transmits the
code at regular intervals. Program the number of
minutes (000 to 255, default = 060) between
transmissions in section [3043].
When armed
: The control panel transmits the test
report code at regular intervals. Program the
number of minutes (000 to 255, default =
005
)
between each transmission in section
[3042]
.
ON OFF
Hourly Test
Transmission
The control panel will transmit the test report code
every hour on the minute value programmed in
section
[3041]
(the last two digits). Note that the
first two digits of section
[3041]
will be ignored.
ON ON
Timed and
Hourly Test
Transmission
The test report code will be transmitted when any
of the conditions of the second and third options
listed above (options
[3]
= OFF and
[4]
= ON /
options
[3]
= ON and
[4]
= OFF) are met.
Partition 1:
[3123]
Partition 3:
[3323]
Partition 5:
[3523]
Partition 7:
[3723]
Partition 2:
[3223]
Partition 4:
[3423]
Partition 6:
[3623]
Partition 8:
[3823]