Appendix 3: Keypad Installation Instructions
1.1 Keypad Installation Instructions
1.1.1 Connecting the Keypads
The keypads are connected to the control panel's combus in a star and/or
daisy chain configuration. Connect the four terminals labeled red, black,
green and yellow of each keypad to the corresponding terminals on the
control panel.
1.1.2 Connecting Keypad Zones
Each keypad has one hardwired input terminal, allowing you to connect one
detector or door contact directly to it. Connect the device to the keypad's
input terminal as shown in
on page 3. In order to communicate its
status to the control panel, the keypad's input must be assigned to a zone in
the control panel and the zone's parameters must be defined.
1.1.3 Programmable Output
Each keypad has one on-board PGM. Upon activation, the PGM can
provide 50mA to any device connected to it. If the current drawn is to
exceed the current limit, a relay should be connected to the PGM as shown
in
2.1 Keypad Specific Instructions
2.1.1 Memory Key Connection
A memory key can be used to download programming to the EVO641 and
EVO641R keypads.
2.1.2 Memory Key
S
ECTIONS
[510]
AND
[520]
Download information using the memory key (PMC-4).
2.1.3 Download Contents of Memory Key to Keypad
S
ECTION
[510]
1.
Insert the memory key into the keypad’s connector labelled “
KEY
.”
2.
To download the contents of the memory key, enter the keypad’s
programming mode and enter section
[510]
.
3.
When the keypad emits a confirmation beep, wait 5 seconds and
remove the memory key after the second confirmation beep.
2.1.4 Copy the Keypad Contents to the Memory Key
S
ECTION
[520]
1.
Insert the memory key onto the keypad’s connector labelled “
KEY
.”
Ensure that the write protect jumper is ON.
2.
To copy the contents to the memory key, enter the keypad’s
programming mode and enter section
[520]
.
3.
After the confirmation beep, wait 5 seconds and remove the memory
key after the second confirmation beep. Set the memory key’s jumper
to OFF if you do not wish to accidentally overwrite its contents.
Figure 23: PMC-4 Jumper Settings
2.2 EVO641R Access Control Connection
Figure 24: : Typical Access Control Installation
Figure 25: : Access Control Overview
Figure 26: : Access Control Connections
Section
[510]
=
Download all from the memory key (LCD keypad
sections
[001]
to
[396]
and all messages) to the
LCD keypad.
Section
[520]
=
Copy the LCD keypad sections
[001]
to
[396]
and
all messages to the memory key.
Jumper On
Jumper Off
1 = Request for Exit (REX) device (Paradoor)
2 = Door contact
3 = EVO641R LCD Keypad Module
4 = Locking device
5 = Control panel (EVO)
5
4
3
1
2
Door
Contact
(Z1)
Locking
Device
(PGM)
REX device (Z2)
EVO641R
Combus
To EVO control
panel
EVO641R
EVO641R
Fused external
power supply
(recommended)
Door Lock
IN4007
Diode
EVO641R
Paradoor (460)
Request to Exit device.
Must be connected to
Z
2
terminal.
If a door contact is not being used, install a jumper or a 1k
W
resistor across the
BLK
and
Z
1 terminals depending on the control panel’s EOL definition.
If the REX (Request for Exit) device is not being used, place a jumper across
the
BLK
and
Z
2 terminals.
Door Contact
Must be connected
to
Z
1
terminal.
* Follows control panel’s EOL definition.
No EOL
required
for
Z
2
.