EVO Control Panel
9
4
Zone Programming
Enter Section [0400], then
enter the number of the
zone you want to program
Enter the zone’s 8-digit
serial and 3-digit input
number (The input number
is not needed for module
with only one input)
Enter the zone’s parameters
(01) (*2*****) default
Enter the zone’s report
codes
(00) (00) (00) (00) default
Enter the zone’s label
Press [ENTER] to save and
go to the next zone
Pressing [CLEAR] twice will
exit the zone programming
menus. Press [ENTER]
before pressing clear to
save your modifications.
Zone Definition
Partition
Zone Option
_____
_____
1 2 3 4 5 6 7 8
0 - Disabled
(default)
1
- Entry Delay 1
2
- Entry Delay 2
3
- Follow
4
- Instant
5
- 24Hr Buzzer
6
- 24Hr Burglary
7
- 24Hr Hold-up
8
- 24Hr Gas
9
- 24Hr Heat
A
- 24Hr Water
B
- 24Hr Freeze
C
- Delayed 24Hr
Fire
D
- Standard 24Hr
Fire
E
- Stay Delay 1
F
- Stay Delay 2
1 - Assigned to Partition 1
(default)
2
- Assigned to Partition 2
3
- Assigned to Partition 3
4
- Assigned to Partition 4
5
- Assigned to Partition 5
6
- Assigned to Partition 6
7
- Assigned to Partition 7
8
- Assigned to Partition 8
[1]
Auto Zone Shutdown Enabled
[2] Bypass Enabled
(default)
[3]
Stay Zone
[4]
Force Zone
[5]
[6]
Zone Alarm Type
off
off
Steady Alarm
off
on
Pulsed Alarm
on
off
Silent Alarm
on
on
Report Only
[7]
Intellizone
[8]
Delay before Transmission
.
Ademco slow, Silent Knight fast, SESCOA, Ademco express or Pager formats:
Key-in desired 2-digit hex values from 00 to FF.
Ademco format:
Use section
[4032]
to program a set of default Ademco report codes from the
on page 26. Then to program the remaining report
codes or to change some of the defaults, enter the individual sections and key-in
the desired 2-digit hex value found in the
Appendix 2: Contact ID Report Code List
SIA format:
Use section
[4032]
to program a set of SIA report codes from the
on page 26. Codes that have not been set to default can be set to
default manually by entering FF in the appropriate section. To disable the reporting
of an event, enter 00 in the appropriate section
Alarm Report Code
Alarm Restore
Report Code
Tamper Report
Code
Tamper Restore
Report Code
__ / __
__ / __
__ / __
__ / __
In any Zone Programming option, pressing [ACC] will save the data and go
to the next zone on the same option screen. Pressing [TRBL] will save the
data and go to the previous zone on the same option screen.
Input
2
Hardwired
Device B
Control Panel
SN#:020000A2
APR3-ZX8 Module
SN#: 34000041
Input 5
Detector A
SN#: 21000033
C
OMMUNICATION
N
ETWORK
Input Terminals
1 2 3 4 5 6 7 8
Detector A:
Hardwired Device A:
Hardwired Device B:
Hardwired Device C:
Zone#
1 =
2 =
3 =
4 =
Section#
[0001]
[0002]
[0003]
[0004]
Serial#
21000033
1A000252
020000A2
34000041
Input#
N/A
N/A
002
005
Keypad
SN#: 1A000252
Keypad Zone
Hardwired
Device C
Hardwired
Device A
Input Terminals
1 2 3 4 5 6 7 8
Combus