![Digi XGI-20CZ7-E00-W0 Скачать руководство пользователя страница 96](http://html1.mh-extra.com/html/digi/xgi-20cz7-e00-w0/xgi-20cz7-e00-w0_user-manual_2496341096.webp)
Configure XBee Industrial Gateway
Ethernet IP network settings
Digi XBee Industrial Gateway
96
Interface Configuration
n
Enable this network interface
: Enables or disables the Ethernet network interface.
n
Speed
: The Ethernet speed that XBee Industrial Gateway uses on the Ethernet network.
l
Automatic
: The device senses the Ethernet speed of the network and adjusts
automatically. The default is
Automatic
. If one side of the Ethernet connection is using
auto (negotiating), the other side can set the Ethernet speed to whatever value is desired.
Or, if the other side is set for
100
Mbps, this side must use
100
Mbps.
10
: The device operates at 10 megabits per second (Mbps) only.
l
100
: The device operates at 100 Mbps only.
n
Duplex Mode
: The mode that XBee Industrial Gateway uses to communicate on the Ethernet
network. Specify one of the following options:
l
Automatic
: The device senses the mode used on the network and adjusts automatically.
The default is
auto
. If one side of the Ethernet connection is using
auto
, the other side can
set the duplex value to whatever is desired. If one side uses a fixed value (for example,
half-duplex
), the other side has to use the same duplex mode.
Full Duplex
: The device communicates in full-duplex mode.
Half Duplex
: The device communicates in half-duplex mode.
Stored IP Configuration
You can set the IP address for XBee Industrial Gateway either automatically, using DHCP, or by
assigning a static IP address. You must enable either the
DCHP
or the
Static IP
option.
n
DHCP
: Select
On
to enable DHCP to assign an IP address to the gateway. XBee Industrial
Gateway uses a DHCP server to obtain its IP address information, by default. A DHCP server
needs to provide an IP address, subnet mask, default gateway, and Domain Name System
(DNS) server for the device. If you disable DHCP, you must enable the
Static IP
option and
configure these settings manually.
In the absence of a DHCP server, you must assign a static IP address by accessing the Digi
Device Discovery tool and changing the network settings through that interface.
n
AutoIP
: Enables or disables use of AutoIP address assignment. When AutoIP is enabled, XBee
Industrial Gateway automatically self-configures an IP address when an address is not
available from other methods. For example, when the Digi device is configured for DHCP and a
DHCP server is not currently available. For more information on AutoIP, see
Configuration of IPv4 Link-Local Addresses
n
Static IP
: Select
ON
to enable you to specify a static IP address for XBee Industrial Gateway.
You must specify the following:
l
IP Address
: The IP address assigned to network devices.
l
Subnet Mask
: The subnet mask assigned to the device. The subnet mask is combined with
the IP address to determine which network this Digi device is part of.
Содержание XGI-20CZ7-E00-W0