Configure XBee Industrial Gateway
Configure Remote Manager connectivity settings
Digi XBee Industrial Gateway
108
4. Complete the fields under
Advanced Settings
. See
Advanced connectivity settings for the web
.
5. Click
Apply
to save your changes.
Device Cloud Configuration page
The default settings for Remote Manager usually work for most situations. You can configure the idle
timeout for the connection between XBee Industrial Gateway and Remote Manager, and the keep-
alive settings of the various interfaces (TCP and HTTP for mobile and Ethernet network connections).
Only change these settings when the defaults settings do not work properly.
Connection Type
Leave this set to
SSL
, which is the default option.
Server List
Up to four servers can be configured in the server list. The value for this setting is generally a Fully
Qualified Domain Name (FQDN) pointing to one of the Remote Manager servers. Obtain this value
from your Remote Manager server administrator. Typically this administrator is Digi.
The default value for
Server List: 1
is
Server TCP Port
The network port number for the Remote Manager server. The default value is 3199.
Proxy server address
This setting specifies the URL of the system that provides network access.
The
Proxy server address
works in conjunction with the
Proxy server TCP port
field. These settings
configure XBee Industrial Gateway to connect to Remote Manager using HTTP over proxy. You can
create a path to a Remote Manager server through a local HTTP proxy, such as squid, provided that
you use the server to simply remap the target IP address and port number, without extra
authentication or other security measures.
Proxy server TCP port
The port number forwards network connection attempts to the Remote Manager server. Obtain
these values from your Remote Manager server administrator.
Connection idle timeout (seconds)
Enables or disables the idle timeout for the Remote Manager connection between device and server.
The idle timeout is enabled by default. Specifying
Disabled
disables the idle timeout. Specifying a
timeout value enables the idle timeout, which means the connection will be dropped after the
specified number of seconds. The minimum value is 300 and the maximum 43200.
Protocol compression enable
Configures whether RCI command and response text is compressed, when both are passed between
the Digi device and the Remote Manager server. This compression primarily affects the size of the
data passed when settings or state information are formatted as RCI and conveyed between device
and server. Using compression on this RCI text can reduce the size of passed data, and, for cellular
products, reduce the cost of reading and writing device settings. When you enable RCI compression,
the RCI command and response text is compressed using LIBZ compression when it is sent between
device and server. The protocol used to manage and pass data between devices and Remote
Manager, known as EDP, internally negotiates whether compression is applied. RCI compression is
enabled, or “on” by default to reduce byte count and cost of sending data. As an example of savings,
typical cellular router settings will compress to about 8% of its original size, which means that you can
send data in far fewer packets and less time, than an uncompressed version of the same data. Only
disable RCI compression for technical support and troubleshooting purposes. For example, if you want
to eliminate the possibility that this compression is causing some sort of problem.