Configure XBee network settings
XBee network OTA firmware updates
Digi XBee Industrial Gateway
125
n
Backup
: The
Backup
operation saves the node’s XBee RF module configuration settings to a
file. The resulting backup file is a .pro file that is compatible with the XCTU configuration tool.
This means that you can save or load backup files from the XBee RF module using XCTU as well
as the gateway’s command line or web interfaces.
n
Choose File
: Provide the path to the backup file with the .pro extension.
n
Restore
: The
Restore
operation sets the node’s XBee RF module configuration settings to
those in the specified .pro file.
CAUTION!
A restore operation may cause the device to reset its network
information, reset, and rejoin a network. It may no longer be accessible from this
gateway.
XBee network OTA firmware updates
The XBee Industrial Gateway firmware supports an OTA (Over the Air) firmware update in the XBee
network nodes. As XBee networks can involve a large number of nodes, Digi provides a way to
automatically schedule XBee Industrial Gateway firmware updates and manage firmware files.
OTA firmware update files are available for downloading from the
. Go to the
firmware update page for the type of XBee ZigBee modules that you want to update. The files must
have the extension .ebl.
Update the XBee network node firmware (OTA updates) from
Remote Manager
You must enable OTA (Over the Air) firmware updates on the device and download the firmware
before you can apply the firmware update to the device.
Step 1: Enable OTA Firmware updates on a device
Before you can perform an OTA firmware update, you must enable that option.
1. Log in to
2. Click the
Device Management
tab.
3. Select the device on which you want to enable OTA firmware updates and automatic firmware
updates.
4. Right-click on the selected device and choose
Properties
.
5. Choose
Advanced Configuration
>
XBee
.
6. Enable the
OTA firmware updates
setting by selecting the
On
option.
7. Enable the
Automatic OTA updates
setting by selecting the
On
option.
8. Click
Save
to save the changes.
Step 2: Download the firmware