EN
AC T I VAT I O N
DiBO 28
1
Temperature settings
Determine experimentally which engine speed (spray pressure) and at which
temperature the object best can be cleaned without damaging it.
Protein-containing material, rubber or synthetic material: knob not higher than
50°C. For the other settings the most diverge materials and/or machines will be
cleaned. Therefore, there are no fixed settings to be displayed.
2
High cleaning temperatures
A cleaning temperature of more than 95°C can only be obtained by reducing
the number l/min produced by the high pressure pump. By reducing the engine
speed setting on the display you reduce the number of l/min. The temperature
shall increase until the maximum set value is reached. If the flow is low, the flow
switch shall put the burner out of use, to prevent that the temperature will
increase to high. On the left & right side you can check the tank levels (CNG &
water).
When the level will decrease below 20%, the display will visualize the level in
red color. Above 20%, the filling level will be displayed in green color.
Below the temperature indication you can see if the burner is active or not. If
you move the control stick 1x up & 1x down, the burner will turn off. Temperature
indication becomes 0° C. The burner hours are visible on the main screen if
pushed on the clock indication. These burner hours will only be visible at the
moment of pushing the (clock) key.
3
Safety message screen
The screen below is always visible. This screen remains visible as long as no
further action is taken. Move the control lever to the left to make the message
disappear.