** Step 8 -
Adjust the Inlet Filter / Regulator
Goal:
Apply air to the system, adjust the incoming regulator, and verify air quality
Be certain that nothing is going to interfere with the cylinder extending or retracting, and
apply air line pressure to the system by switching on the OSHA-approved shutoff switch on
the inlet filter/regulator. Adjust the regulator by
lifting up on the knob and rotate clockwise to
increase the system air pressure. View the
pressure setting on the pressure sensor digital
display, located on the air manifold. Set the
pressure between 60 and 100 psi. Once the
correct pressure is set, press down on the knob
to lock it in position. Remove the knob entirely by
lifting it up past the unlock point, if there is
concern about system tampering.
TAMP
FASA
Step 9 -
Position the Nip Roller
Goal:
Set the nip roller to the mid-point of the label width.
To ensure that the liner tracks straight through the system, position the nip roller on the
mid-point of the liner. This is accomplished by using a set of snap ring pliers. First, remove
the outer snap ring and washer. Remove the nip roller. Position the inner snap ring and
washer to allow the nip roller to be placed in the center of the liner. Re-install the roller,
followed by the washer and then snap ring. Seat the ring snug.
Diagraph - an ITW Company LA/4700 User Manual - Revision B
Setup
Page 23
Setup
Содержание LA/4700
Страница 1: ...4700 010 Revision B...
Страница 61: ...Diagraph an ITW Company LA 4700 User Manual Revision B Maintenance Page 60 Maintenance...
Страница 62: ...Diagraph an ITW Company LA 4700 User Manual Revision B Maintenance Page 61 Maintenance...
Страница 63: ...Diagraph an ITW Company LA 4700 User Manual Revision B Maintenance Page 62 Maintenance...