51
Chapter 4 Read This Chapter Whenever You Face a Problem. (FAQ)
Responding to an Error Message
This section describes the error messages that may appear on VPanel window, and how to take action to remedy the problem.
If the action described here does not correct the problem, or if an error message not described here appears, contact your
authorized Roland DG Corporation dealer.
The limit switch of the displayed axis cannot be detected. Turn off the power, remove the objects which block the operation
of the machine and accumulated cutting waste, if any, and then restart the machine.
The cutting conditions may be excessively strict. Review the settings of CAM and the shape specified in the cutting data.
Cutting waste may hinder the operation of the machine. Clean the machine.
Release the tool forcibly by following the message of VPanel. After the tool was removed, clean the inside of the collet and
the magazine. If the same error recurs even after the inside of the collet was cleaned, the collet may be deformed. In this
case, replace the collet.
The tool moved out of position or was damaged due to a large load on the tool. The cutting conditions may be excessively
strict. Review the settings of CAM and the shape specified in the cutting data. If the same message appears even after the
cutting data was reviewed, the tool may be worn. Replace it with a new one.
The machine will come to an emergency stop if the front cover is opened when the spindle is rotating. Turn off the power,
and close the front cover, and then restart the operation from the beginning.
Replace the tool with one of proper length (length: 40 to 55 mm). There is a possibility that the position of the tool holder is
not correct. Check the position of the tool holder.
P. 22, "STEP2 : Attaching a Tool"
1000-**** % limit switch is not found.
(% is any of "X", "Y", "Z", or "A".)
1006-**** % motor position is lost.
(% is any of "X", "Y", "Z", or "A".)
101D-**** The % tool cannot be released.(% may be "1 to 4")
101E-**** The % tool might be broken. (% may be "1 to 4")
101F-**** The % tool chucking has slipped out.(% may be "1 to 4")
1017-0000 Cover opened during operation.
1020-**** The % tool is too long.(% may be "1 to 4")
1021-**** The % tool is too short.(% may be "1 to 4")
Содержание DWX-4