Field Service Ver. 1.0 Apr. 2005
10. Service Mode
85
ineo 161
ineo 210
Adjustment / Setting
For ineo 210
G. FUSER TEMP. Ad (THICK)
<Temperature table for adjusting fusing temperature for special paper>
For ineo 161
For ineo 210
Setting value
Paper width
Mode selected in Service’s Choice
Mode 1
Mode 3
Fusing Heater Lamp temperature (main/sub)
2
221 mm or more
200
°
C
220 mm or less
1
221 mm or more
190
°
C
220 mm or less
0 (default value)
221 mm or more
180
°
C
220 mm or less
-1
221 mm or more
170
°
C
220 mm or less
Purpose/Use
To set the fusing temperature when thick paper is used.
✽
When fusing failure occurs
Setting/
Procedure
• The default setting is “0.”
Setting range: -1 to +1
Setting value
Paper width
Mode selected in Service’s Choice
Mode 1
Mode 3
CD
Fusing Heater Lamp temperature
1
251 mm or more
210
°
C
200
°
C
250 mm or less
210
°
C
200
°
C
0 (default value)
251 mm or more
210
°
C
190
°
C
250 mm or less
200
°
C
190
°
C
-1
251 mm or more
200
°
C
180
°
C
250 mm or less
190
°
C
180
°
C
Setting value
Mode selected in Service’s Choice
Mode 1
Mode 3
Fusing Heater Lamp temperature (main/sub)
1
210
°
C
0 (default value)
200
°
C
-1
190
°
C