12. Mechanical adjustment
Field Service Ver. 1.0 Apr. 2005
110
ineo 161
ineo 210
Adjustment / Setting
12. Mechanical adjustment
12.1 Adjustment of the Position of the Scanner and 2nd/3rd Mir-
rors Carriage
NOTE
• This adjustment is to be made when the Scanner Drive Cables has been replaced
or rewound.
1.
Remove the Original Glass.
☞
2.
Fit the Scanner/Mirrors Carriage
Positioning Jigs in position. Then,
press the 2nd/3rd Mirrors Carriage
up against the jigs.
3.
Loosen the fixing screws and adjust
as necessary so that there is no
clearance between the 2nd/3rd Mir-
rors Carriage and the jigs.
4.
Press the Scanner up against the jigs and tighten the fixing screws.
NOTE
• When the Scanner Assy is secured
to the Scanner Drive Cables using
the fixing brackets, make sure that
the cables are located as shown on
the left.
If the cables are not positioned
properly, the Scanner Assy can
move askew, resulting an image
problem.
4035D106AA
4035D107AA
4035D108AB
4035D527AA
<Cross-sectional View>
Cable
Содержание ineo 161
Страница 1: ...ineo 161 ineo 210 Dynamic balance www develop de Service Manual Field ...
Страница 2: ......
Страница 4: ......
Страница 76: ...6 Other Field Service Ver 1 0 Apr 2005 66 ineo 161 ineo 210 Maintenance Blank page ...
Страница 188: ...17 Image quality problem Field Service Ver 1 0 Apr 2005 178 ineo 161 ineo 210 Troubleshooting Blank page ...