Field Service Ver. 1.0 Apr. 2005
15. Malfunction code
145
ineo 161
ineo 210
T
roubleshooting
15.3.14
C0F32: Faulty ATDC Sensor
15.3.15
C0F33: Improperly Adjusted ATDC Sensor
A. Detection Timing
B. Action
Trouble Code
Description
C0F32
• The measurement taken by the ATDC Sensor (UN1) at a time 2.0 sec. after the
Main Motor (M1) has started turning is less than 5% (greater than 4.63 V).
• The measurement taken by the ATDC Sensor (UN1) at a time 2.0 sec. after the
Main Motor (M1) has started turning is 19% or more (1.41 V or less).
C0F33
• The adjustment of the ATDC control voltage is not completed within 1 sec. after
sampling has started of the ATDC Sensor (UN1) as part of an operation of
ATDC Sensor Automatic Adjustment.
• The ATDC Sensor control voltage falls outside the range of 5.39 V to 8.15 V
during an operation of ATDC Sensor Automatic Adjustment.
Relevant Electrical Components
ATDC Sensor (UN1)
Master Board (PWB-A)
Power Supply Unit (PU1)
Step
Operations
Ref.
Page
WIRING DIAGRAM
Control signal
Location
(Electrical
Components)
1
Check to see if developer is available.
–
–
–
2
Check the ATDC Sensor connectors
for proper connection and correct as
necessary.
–
–
–
3
Change UN1.
–
–
–
4
Run “ATDC Auto Adjust.”
☞
–
–
5
Change PWB-A.
–
–
–
6
Change PU1.
–
–
–
Содержание ineo 161