17. Image quality problem
Field Service Ver. 1.0 Apr. 2005
156
ineo 161
ineo 210
T
roubleshooting
17.2.2
Image Reading Section: black copy
A. Typical Faulty Images
B. Troubleshooting Procedure
4011T036AA
Step
Check
Result
Action
1
Exposure Lamp turns ON when the Power Switch is turned
ON.
NO
Go to step 3.
2
Exposure Lamp is abnormally lit (flickers or abnormally
dark) when the Power Switch is turned ON.
NO
Go to step 4.
3
Inverter Board (PU2) connector is loose.
YES
Reconnect.
NO
Change Exposure Lamp.
4
CCD Board (PWB-J) connector is loose.
YES
Reconnect.
5
Control Board (PWB-C/C) connector is loose.
YES
Reconnect.
NO
• Change Inverter Board
(PU2).
• Change CCD Unit.
• Change Control Board
(PWB-C/C).