Field Service Ver. 1.0 Apr. 2005
6. Other
57
ineo 161
ineo 210
Maintenance
4.
Unplug two connectors and remove
the Paper Size Sensor Assy.
6.3.22
Fusing Unit Interlock Switch
1.
Remove the Rear Cover.
☞
2.
Remove the harness from one wiring
saddle.
3.
Remove two screws (to which red
paint has been applied).
4.
Unplug four connectors and remove
the Fusing Unit Interlock Switch
Assy.
NOTE
• When installing the Fusing Unit
Interlock Switch Assy, make sure
that the connectors are connected
properly.
4035D103AA
4035D130AC
4035D131AA
4035D132AA