Seite 92
© 06/02
EMR 2
Diagnostic Button and
Fault Indicator Lamp
1
2
3
4
5
6
7
8
9
10
11
12
12
7.2.2
Deletion of the fault memory 1
The EMR 2 has two fault memories (1 and 2). Every fault is stored in both memories at the same time. With
the aid of the diagnostic button it is possible to delete
passive
faults in fault memory 1. The fault memory 2
can only be deleted with SERDIA.
The following shows the steps for deleting the fault memory 1:
a
Press, and keep depressed, the diagnostic button.
b
Switch ignition on.
c
Whilst the fault indicator lamp is lit up (duration 2 s) release diagnostic button.
d
All
passive
faults in faults in fault memory 1 are deleted.
e
The deletion process is confirmed by three short flash impulses.
© 06/02
On
Off
Time
Diagnostic button
Fault indicator lamp
On
Off
Time
0.
4
s
0.
4 s
On
Off
Time
Key switch (terminal 15)
2 s
< 2 s
a
b
c
d
e