
© 06/02
Seite 89
EMR 2
Diagnostic Button and
Fault Indicator Lamp
1
2
3
4
5
6
7
8
9
10
11
12
13
Function control of the configured warning lamps
With the activation of the key switch (pin 15), the warning lamp is also switched on for the duration of the
self-diagnostic (2 s).
On
Off
Time
2 s
On
Off
Time
© 06/02
Key switch (terminal 15)
On
Off
Time
Fault indicator lamp
2 s
e.g. warning lamp oil pressure
Содержание EMR 2
Страница 1: ...System Description Electronic Engine Governor EMR 2...
Страница 2: ......
Страница 4: ...Page 62 06 02 EMR 2 Chapter Overview 1 2 3 4 5 6 7 8 9 10 11 12 12...
Страница 8: ...1 2 3 4 5 6 7 8 9 10 11 12 12 Page 66 06 02 EMR 2 Introduction...
Страница 26: ...1 2 3 4 5 6 7 8 9 10 11 12 12 Page 84 06 02 EMR 2 Interfaces...
Страница 50: ...1 2 3 4 5 6 7 8 9 10 11 12 12 Page 108 06 02 EMR 2 Index of Specialist Terms...
Страница 54: ...1 2 3 4 5 6 7 8 9 10 11 12 13 Seite 112 06 02 EMR 2 Index...
Страница 56: ......