background image

Table 30 – Part list single stage PSC

#

Description

C45-1-D

C60-1-D

C75-1-D

C105-1-D

C120-1-D

1

Back panel assembly

B40511-04

B40511-05

B40511-05

B40511-06

B40511-06

2

Right panel assembly

B40510-34

B40510-34

B40510-34

B40510-34

B40510-34

3

Part bag

B40569-01

B40569-02

B40569-02

B40569-02

B40569-02

4

PVC Tube 1/2"

B30157-38

B30157-38

B30157-38

B30157-38

B30157-38

5

PVC Tube 5/8"

B30157-34

B30157-34

B30157-34

B30157-34

B30157-34

6

Square tube 3/16"

B30157-26

B30157-26

B30157-26

B30157-26

B30157-26

7

Floor

B40546-01

B40546-02

B40546-02

B40546-03

B40546-03

8

Blower assembly

B40518-01

B40518-04

B40518-02

B40518-03

B40518-03

9

Electric wire blower

B40590-02

B40590-02

B40590-02

B40590-02

B40590-02

10

Restriction disk

B40699

B40563-04

B40698

B40563-06

N/A

11

Pressure switch assembly

B40675-03

B40675-04

B40675-05

B40675-07

B40675-08

12

Gas valve single stage

R01H012

R01H012

R01H012

R01H012

R01H012

13

Control box assembly

B40697

B40697

B40697

B40697

B40697

14

Lower door assembly

B40570-01

B40570-02

B40570-02

B40570-03

B40570-03

15

Upper door assembly

B40571-01

B40571-02

B40571-02

B40571-03

B40571-03

16

Left panel assembly

B40509-01

B40509-01

B40509-01

B40509-01

B40509-01

17

Electric kit main harness

B40591-02

B40591-02

B40591-02

B40591-02

B40591-02

18

Electric kit inducer/ignitor

B40589-01

B40589-01

B40589-01

B40589-02

B40589-02

19

Complete inducer blower ass.

B40578-04

B40578-01

B40578-01

B40578-01

B40578-01

20

Top panel assembly

B40512-01

B40512-02

B40512-02

B40512-03

B40512-03

20

Complete manifold assembly

B40514-03

B40514-04

B40514-05

B40514-07

B40514-08

21

Kit extruded sealant

B04435-01

B04435-01

B04435-01

B04435-01

B04435-01

22

Dettson observation port

B40565

B40565

B40565

B40565

B40565

23

Observation port

L04Z022

L04Z022

L04Z022

L04Z022

L04Z022

24

Grommet

G14F017

G14F017

G14F017

G14F017

G14F017

25

Complete manifold assembly

B40514-03

B40514-04

B40514-05

B40514-07

B40514-08

26

Pressure switch support

B40560

B40560

B40560

B40560

B40560

27

Pressure switch (multiposition)

R99F035

R99F035

R99F035

R99F035

R99F035

28

Pressure switch (high fire)

R99F043

R99F042

R99F048

R99F039

R99F039

29

Drain trap gasket

B40568

B40568

B40568

B40568

B40568

30

Black venting gasket

B40903

B40903

B40903

B40903

B40903

31

Venting flange gasket

B40567

B40567

B40567

B40567

B40567

32

Drain trap

B40760

B40760

B40760

B40760

B40760

33

Venting flange

B40533

B40533

B40533

B40533

B40533

34

Ignitor 120V

R03K005K

R03K005K

R03K005K

R03K005K

R03K005K

35

High limit burner box

R02N022

R02N022

R02N022

R02N022

R02N022

36

Manifold (item 37 included)

B40527

B40528

B40529

B40531

B40532

37

Orifice #48 natural gas

R04I001

R04I001

R04I001

R04I001

R04I001

38

Flame sensor

R03J005

R03J005

R03J005

R03J005

R03J005

39

Burner Box

B40908-03

B40908-04

B40908-05

B40908-07

B40908-08

40

Clamp 5/8"

G99Z035

G99Z035

G99Z035

G99Z035

G99Z035

41

Elbow 5/8"

G07J007

G07J007

G07J007

G07J007

G07J007

42

Condensate box

B40526-01

B40526-02

B40526-02

B40526-03

B40526-04

43

Heat exchanger thermodisk

R02N026

R02N024

R02N023

R02N024

R02N024

44

Turbulator

B40572

B40572

B40572

B40572

B40572

45

Smoke box

B40539-01

B40539-02

B40539-02

B40539-03

B40539-04

46

Transformer 120v-24v

L01F009

L01F009

L01F009

L01F009

L01F009

47

Control board support

B40559

B40559

B40559

B40559

B40559

48

Control board 1 stage

R99G013K

R99G013K

R99G013K

R99G013K

R99G013K

49

1/2" black cap

G14G013

G14G013

G14G013

G14G013

G14G013

50

Inducer blower 1 stage

Z01K007K

Z01K007K

Z01K007K

Z01K007K

Z01K007K

51

Elbow 1/2"

G07J006

G07J006

G07J006

G07J006

G07J006

52

Sleeve drain

N/A

B40913

B40913

B40913

B40913

53

Clamp 1/2"

G99Z034

G99Z034

G99Z034

G99Z034

G99Z034

54

Hose clamp 2-3"

G99Z033

G99Z033

G99Z033

G99Z033

G99Z033

55

Rubber vent flange

B40580

B40580

B40580

B40580

B40580

56

Blower

Z01I033

Z01I035

Z01I036

Z01I038

Z01I038

57

Capacitor support

B01024

B01024

B01024

B01024

B01024

58

Capacitor

L01I002

L01I002

L01I005

L01I003

L01I003

59

Belly band kit

B01889

B01889

B01889

B01889

B01889

60

PSC motor

L06H004

L06H004

L06I004

L06K004

L06K004

61

PSC motor assembly (item 59 included)

B03684-02

B03684-03

B01891-07

B01891-08

B01891-08

62

Door switch

L07H001

L07H001

L07H001

L07H001

L07H001

Inducer blower and PVC elbow ass

B40766-01

B40766-01

B40766-01

B40766-01

Kit PVC elbow

B40818

B40818

B40818

B40818

Bottow return base

B40691-01

B40691-02

B40691-02

B40691-03

B40691-03

Downflow base

B40632-01

B40632-02

B40632-02

B40632-03

B40632-03

Cooling coil support

B40693-01

B40693-02

B40693-02

B40693-03

B40693-03

Propane conversion kit

B40574-07

B40574-10

B40574-13

B40574-19

B40574-22

Orifice #56 propane

R04I002

R04I002

R04I002

R04I002

R04I002

44

Содержание C105-1-D

Страница 1: ...old in US and Canada INSTALLER SERVICE TECHNICIAN Use the information in this manual for the installation servicing of the furnace and keep the document near the unit for future reference HOMEOWNER Pl...

Страница 2: ...MET 14 5 4 SETTING GAS OUTLET PRESSURE 14 5 4 1 Adjusting 2 stage gas valve 15 5 4 2 Adjusting single stage gas valve 15 6 ELECTRICAL CONNECTIONS 17 6 1 120V WIRING 17 6 2 24V WIRING 17 6 3 FUSE 17 6...

Страница 3: ...Stage PSC Wiring diagram 33 Figure 33 Two Stage PSC Wiring diagram 34 Figure 34 Single Stage ECM Wiring diagram 35 Figure 35 Dimensions 38 Figure 36 Exploded view CXX 1 X part 1 39 Figure 37 Exploded...

Страница 4: ...assess the damage and to replace all critical parts that were in contact with water 3 Do not store gasoline or any other flammable substances such as paper or carton near the furnace 4 Do not stack it...

Страница 5: ...o be handled by duct s sealed to the furnace casing and terminating outside the space containing the furnace See section 4 DUCT INSTALLATION This furnace may be installed with a two pipe sealed combus...

Страница 6: ...th the National Fuel Gas Code ANSI Z223 1 NFPA 54 and or Natural Gas and Propane Installation code CSA B149 1 9 After it has been determined that each appliance connected to the venting system properl...

Страница 7: ...ng Systems ANSI NFPA 90B National Standard of Canada Natural Gas and Propane Installation Code NSCNGPIC CAN CSA B149 1 General installation NFGC and the NFPA 90B For copies contact the National Fire P...

Страница 8: ...water Not be installed directly on any combustible material other than wood flooring Be located close to the chimney or vent and attached to an air distribution system Refer to section 7 Place the un...

Страница 9: ...r slightly leaned forward to help drain condensate 3 1 1 Right side condensate drain trap connection Figure 1 Right side connection See figure 1 and read the following instructions 1 Remove the oblong...

Страница 10: ...supply duct going through the floor and the proper slope of the furnace for condensate drainage Also the base allows sufficient spacing for the venting and the drain trap When installing the furnace...

Страница 11: ...ssure switch assembly Figure 5 Connecting pressure switch in downflow position 3 3 HORIZONTAL RIGHT Figure 6 Horizontal right position Figure 7 Horizontal right slope When installing the furnace in ho...

Страница 12: ...on of flue gas 9 On the remaining 5 inlets connect black caps 1x5 8 and 2x1 2 These caps are provided in the parts bag 3 3 2 Horizontal right multiposition pressure switch connection Figure 8 Horizont...

Страница 13: ...ub of the drain trap Cut the provided 5 8 tubing at appropriate length to reach the drain trap 8 Reroute the vent collector drain tube to one of the 1 2 stubs of the drain trap Cut the provided 1 2 tu...

Страница 14: ...n of vibration Many states provinces and localities are considering or have implemented standards and or restrictions on duct sizing practices ductwork leakage and or ductwork thermal airflow and elec...

Страница 15: ...d local codes Refer to current edition of NFGC in the U S A Refer to current edition of CAN CSA B149 1 in Canada Installations must be made in accordance with all authorities having jurisdiction Use a...

Страница 16: ...wise 7in lb minimum 12 Turn on electrical power to the system 13 Make a call for heat on the thermostat 14 Using a leak detection solution or soap suds check for leaks at the pressure boss screw If a...

Страница 17: ...l Gas Propane High fire 100 3 0 8 6 Low fire 70 1 55 5 0 Figure 16 Typical gas pipe arrangement Table 6 Maximum capacity of pipe Cu ft Hr for pipe length ft m Nominal Iron pipe size in mm Internal dia...

Страница 18: ...r cooling operation Use only AWG No 18 color coded copper thermostat wire Use AWG No 18 color coded copper thermostat wire for lengths up to 100ft 30 5m For wire lengths over 100 ft use AWG No 16 wire...

Страница 19: ...1 4 per foot of run so that condensate drains toward the furnace Support horizontal vent piping at least every five feet No sags or dips are permitted The vent pipe and combustion air pipe must termin...

Страница 20: ...nt pipe installations in Canada must conform to the requirements of CAN CSA B149 code PVC and CPVC vent systems must be composed of pipe fittings cements and primers listed to ULC S636 and must be of...

Страница 21: ...distribution of primer and cement 8 Clean and dry all surfaces to be joined 9 Check dry fit of the pipe and mark insertion depth on the pipe 10 After the pipes have been cut and preassembled apply a...

Страница 22: ...allation codes and the requirements of the gas supplier and the instructions in this manual A vent for this appliance shall not terminate over public walkways near soffit vents or crawl space vents or...

Страница 23: ...of or sidewall for vent and combustion air pipes Sidewall holes for two pipes vent terminations should be side by side allowing space between the pipes for the elbows to fit on the pipes Holes in the...

Страница 24: ...Figure 26 Alternate horizontal termination C Figure 27 Venting gasket 23...

Страница 25: ...Figure 28 Direct vent clearance 24...

Страница 26: ...Figure 29 Other than Direct vent clearance 25...

Страница 27: ...light the main burners 3 Set the thermostat to it lowest setting and turn off furnace electrical power 4 Replace the burner compartment control access door WARNING Failure to replace the burner door c...

Страница 28: ...fan on S2 30 sec 45 sec Table 16 Option switch single stage delay to fan off heating HEAT delay DIPSWITCH to fan off S3 S4 60 sec ON ON 90 sec OFF ON 120 sec ON OFF 180 sec OFF OFF 9 3 Cool mode A cal...

Страница 29: ...minal on the control board The unused leads must be connected to the PARK terminal on the control board 5 Turn on power to the furnace 6 Verify proper temperature rise Excessive temperature can cause...

Страница 30: ...cate the 1st stage heating and the blue wire locate de cooling speed 4 If heating and cooling speeds are the same a jumper wire must be used between the heat and cool terminal on the control board The...

Страница 31: ...air it Call a qualified service technician Force or attempted repair may result in a fire or explosion 13 1 WHAT TO DO IF YOU SMELL GAS WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnin...

Страница 32: ...excess dirt from a cleanable filter shake filter and or use a vacuum cleaner Wash filter in soap or detergent water and replace after filter is dry Cleanable filters do not need to be oiled after was...

Страница 33: ...5 9 20 75 000 120 60 1 127 104 13 1 15 5 20 105 000 120 60 1 127 104 16 4 19 7 20 120 000 120 60 1 127 104 16 4 19 7 20 Two Stage ECM motor UNIT VOLT HERTZ PHASE OPERATING VOLT RANGE MAX UNIT UNIT AMP...

Страница 34: ...Figure 32 Single Stage PSC Wiring diagram...

Страница 35: ...Figure 33 Two Stage PSC Wiring diagram...

Страница 36: ...Figure 34 Single Stage ECM Wiring diagram...

Страница 37: ...essure high fire 100 Outlet gas pressure low fire 70 Static pressure in return Static pressure in supply Temperature rise Is drain trap filled with water Is drain trap outlet vented with a Tee Are con...

Страница 38: ...ve Make sure flame rod is clean and properly wired 9 Improper grounding or polarity 120V hot and neutral reversed 120V should be read between Hot and ground 0V should be read between Neutral and groun...

Страница 39: ...Figure 35 Dimensions 38...

Страница 40: ...Figure 36 Exploded view CXX 1 X part 1...

Страница 41: ...Figure 37 Exploded view CXX 1 X part 2...

Страница 42: ...7 26 B30157 26 B30157 26 B30157 26 30 Ignitor R03K005K R03K005K R03K005K R03K005K R03K005K 31 Roll out switch R02N022 R02N022 R02N022 R02N022 R02N022 32 Gas manifold orifice included B40527 B40528 B40...

Страница 43: ...Figure 38 Exploded view Cxx 1 D part 1...

Страница 44: ...Figure 39 Exploded view Cxx 1 D part 2...

Страница 45: ...B40903 B40903 B40903 B40903 B40903 31 Venting flange gasket B40567 B40567 B40567 B40567 B40567 32 Drain trap B40760 B40760 B40760 B40760 B40760 33 Venting flange B40533 B40533 B40533 B40533 B40533 34...

Страница 46: ...Figure 40 Exploded view Cxx 2 D part 1...

Страница 47: ...Figure 41 Exploded view Cxx 2 D part 2...

Страница 48: ...ng gasket B40903 B40903 B40903 B40903 B40903 33 Venting flange gasket B40567 B40567 B40567 B40567 B40567 34 Drain trap B40760 B40760 B40760 B40760 B40760 35 Venting flange B40533 B40533 B40533 B40533...