5
CL3
Series
1.0
Introduction
•
Safety Labels and Their Locations
CL3-40-85N
Please contact the factory for assistance, parts information and/or list prices at 586-756-0950 or visit store.reverberray.com
SERIAL NUMBER: 1711XXXXXXXXXX 0001
PRODUCTION CODE: CL3-C1
COMPONENT
PART NO. DESCRIPTION
CIRCUIT BOARD ......... TP-851B
Fenwal
GAS VALVE ................. TP-1040
24VAC Single Stage
GAS INLET................... TP-84
1/2” NPT to Flare
IGNITER....................... TP-50A
Glo-Bar
IND. LIGHT #1.............. TP-828A
Amber LED Ind. Light
IND. LIGHT #2.............. TP-1428A
Green LED Ind. Light
IND. LIGHT #3.............. NONE
N/A
VERSION
OPTIONS
11/17
None
BILL OF MATERIALS
COMPONENT
PART NO. DESCRIPTION
INDUCER FAN ............. TP-55A
1/20 hp Inducer Assy
POWER ENTRY........... 3239
BX Conduit Connector
RELAY.......................... N/A
N/A
STARTER TUBE .......... TP-3380
HSI-Starter Tube
TERMINAL BLOCK ...... TP-329
Terminal Block
TRANSFORMER.......... TP-826
120Pri 24Sec
WIRE HARNESS.......... TP-353
Wire Harness
MODEL SPECIFIC DATA
TUBE & REFLECTOR PARTS
AIR ORIFICE SIZE ....... TP-3014
1 1/8
BURNER ...................... TP-3072
Green
GAS ORIFICE SIZE .....
29 DMS
1ST PRES. SWITCH .... TP-264E
Glo-Bar
2ND PRES. SWITCH ... N/A
N/A
WIRING DIAGRAM ...... LLWT110
Rev. 1
BAFFLE........................ TP-65I
5
COMB. TUBE ............... TP-26Q
5” Aluminized Lined
HANGERS.................... TP-19E
4” Elong. Galv w/spring
REFLECTORS ............. TP-20C
10’ Aluminum
RADIANT TUBE ........... TP-26A
4” Aluminized
TUBE CLAMP............... TP-21B
4” Galv Clamp
Detroit Radiant Products Company
21400 Hoover Road Warren MI 48089
(586) 756-0950 www.reverberray.com
LOW-INTENSITY INFRARED HEATER
MAX. HEAT INPUT
MAX. DEBIT CALORIFIQUE
MIN. HEAT INPUT
MIN. DEBIT CALORIFIQUE
VENT CATEGORY
ÉVENT CATÉGORIE
BTU/h
BTU/h
VOLTAGE
AMPS
PHASE
FREQUENCY
Hz
VAC
MANIFOLD PRESSURE
PRESSION A LA TUBULURE D'ALIMENTATION
MAXIMUM INLET PRESSURE
PRESSION D'ALIMENTATION MAXIMALE
MINIMUM INLET PRESSURE FOR PURPOSE OF ADJ.
PRESSION D'ALIMENTATION EN GAS MIN. ADMISE
INCHES W.C.
INCHES W.C.
INCHES W.C.
RADIATEUR À INFRAROUGE À FAIBLE INTENSITÉ
ORIFICE SIZE
DIM DE L'INJECTEUR
NATURAL GAS
PROPANE GAS
THIS DESIGN COMPLIES WITH STANDARD(S):
COMPLES DE CETTE CONCEPTION AVEC LA NORME:
HEATER BUILD TYPE
TYPE OF GAS
TYPE DE GAZ
MIN. MOUNTING ANGLE
MIN. ANGLE DE SUPPORT
MAX. MOUNTING ANGLE
MAX. ANGLE DE SUPPORT
MODEL NUMBER
NUMÉRO DE MODÈLE
SERIAL NUMBER
NUMÉRO DE SÉRIE
VERSION
COMBUSTION CHAMBER
FOR COMMERCIAL / INDUSTRIAL USE. FOR INDOOR USE ONLY.
MADE IN U.S.A.
85,000
65,000
CAT. I AND III
4.8
SINGLE
60
120
3.5
14.0
5.0
29
D.M.S.
45
D.M.S.
ANSI Z83.20-2016 • CSA2.34-2016 RADIANT TUBE HEATER
C1
NATURAL
0°
45°
CL3-40
-85N
YYMMREPCSHIPPE####
11/17
TP-26Q; 5” CNG Lined Aluminized
112671
THIS HEATER REQUIRES A SPECIAL VENTING SYSTEM WHEN
INSTALLED AS A CATEGORY I AND III HEATER. REFER TO THE INSTALLATION
INSTRUCTIONS FOR PARTS LIST AND METHOD OF INSTALLATION.
AVOID EQUIPMENT FAILURE
THIS 10 FT. TUBE IS THE
CNG LINED
COMBUSTION CHAMBER.
THIS TUBE MUST BE THE FIRST TUBE
FOLLOWING THE BURNER CONTROL BOX.
!
INSTALLER
The combustion chamber utilizes a black coated
aluminized tube with an internal titanium liner.
Rotate the tube’s welded seam to bottom.
Consult the manual(s) for further details.
LLTB004c-XM-11/17 (DRPC)
AVOID EQUIPMENT FAILURE
THIS 10 FT. TUBE IS THE
FIRST RADIANT TUBE AFTER
THE 5” COMBUSTION TUBE.
THIS TUBE MUST BE THE FIRST TUBE
FOLLOWING THE 5” COMBUSTION TUBE.
!
INSTALLER
The first radiant tube utilizes a black coated
aluminized tube with both ends swedged.
Rotate the tube’s welded seam to bottom.
Consult the manual for further details.
LLTB004d-XM-11/17 (DRPC)
F/N: LLTB004c
(Yellow)
F/N: LLTB004d
(Green)
Controls Compartment
F/N: LLTB026
F/N: LLTB024L
Fan Compartment
16” Burner Tube
5” Combustion Chamber
F/N: LLTB025R
F/N: LL001 - Clearance Safety Tag
(Affix adjacent to heater’s thermostat)
Clearances to combustibles must be maintained at
all times in order to prevent the ignition of
combustible materials. In locations used for the
storage of combustible materials, signs must be
posted to specify the maximum permissible stacking height to
maintain the required clearances from the heater to the
combustibles. Signs must either be posted adjacent to the
heater’s thermostats or, in the absence of such thermostats, in a
conspicuous location. Clearances are provided on the heater’s
safety label and in the heater’s Installation, Operation, and
Maintenance manual. Product installation and operation must
comply with applicable standards, codes, and regulations. Post
this tag adjacent to the heater’s thermostat or controls before
operating the heater.
- INSTALLER: READ AND POST THIS NOTICE -
LL001-XM-07/18 (CDS)
This product can
expose you to
chemicals including
lead and carbon
monoxide, which are known to the
State of California to cause birth
defects or other reproductive harm.
For more information go to
www.P65Warnings.ca.gov.
WARNING
!
Avoid Serious Injury, Death, or Property Damage.
Maintain Clearances to Combustible to Prevent the Risk of Fire.
California Proposition 65
SERVICE ACCESS PANEL
IGNITER & FLAME SENSE COMPARTMENT
1.
Turn off gas & electricity.
2.
Remove cover by lifting top
cover upward and outward.
CAUTION:
HOT SURFACE.
KEEP COVER IN PLACE. REMOVE FOR SERVICE ONLY.
SERVICE ACCESS PANEL
SERVICE ACCESS PANEL
4” Radiant Tube(s)
SAMPLE
SAMPLE
SERVICE ACCESS PANEL
IGNITER & FLAME SENSE COMPARTMENT
1.
Disconnect gas & electricity.
2.
Remove cover by lifting top
cover upward and outward.
CAUTION:
HOT SURFACE.
KEEP COVER IN PLACE. REMOVE FOR SERVICE ONLY.
Burner Control Box Component Label
(located inside the center compartment lid)
Rating
Plate