WARNING
!
4
CL3
Series
1.0
Introduction
•
Safety Labels and Their Locations
Safety Signs and Labels
Product safety signs or labels should be replaced by the product user when they no longer are legible.
Contact either your local distributor or the product manufacturer for obtaining replacement signs or
labels.
Read and understand all safety information and warnings in this manual before
installation, operation, and maintenance of the radiant tube heater system.
24V
LOW
24V OUT
HIGH
- 24V HEATER OUTPUT -
F/N: LLV3EP4
24 V Input (White
crescent - without
relay option)
NEUTRAL
EARTH
HOT
- 120V HEATER INPUT -
120V
NEUTRAL
EARTH
HOT
- 120V HEATER INPUT -
120V
LOW
NEUTRAL
HIGH
24V
- 24V HEATER INPUT -
F/N: LLAC
Air Metering Orifice
Air Metering Orifice
DO NOT REMOVE
TP-114
TP-3014
3”
SAMPLE
SER
VICE
ACCESS P
ANE
L
CONTROLS & GAS
VA
LVE COMP
ARTMENT
1.
Disconnect gas & electricit
y.
2.
Remove four (4) thumbscrews
.
3.
Remove top cove
r.
4.
Swing hinged panel downward.
KEEP
COVER IN PLACE. REMOVE FOR SER
VICE ONL
Y.
SER
VICE
ACCESS P
ANE
L
IGNITER & FLAME SENSE COMP
ARTMEN
T
1.
Disconnect gas & electricit
y.
2.
Remove cover by lifting top
cover upward and outward
.
CAUTION
:
HOT SURF
ACE.
KEEP
COVER IN PLACE. REMOVE FOR SER
VICE ON
LY
.
SER
VICE
ACCESS P
ANE
L
F
AN COMP
ARTMENT
1.
Disconnect gas & electricit
y.
2.
Remove top cover (2 thumbscrews).
3.
Remove tsix (6) 1/4” screws.
4.
Lift and remove panel.
KEEP
COVER IN PLACE. REMOVE FOR SE
RV
ICE ONL
Y.
Back Panel
Top Panel
Bottom Panel
F/N: LLTB018
(Natural Gas)
F/N: LLTB019
(Prop. Gas)
F/N: LLTCL006L, LLTCL019, LLTCL001R
Clearances to Combustibles Labels
F/N: LLV3EP1
120V Input
F/N: LLV3EP14
(Operational Indicator Lights)
!
CLEARANCES TO COMBUSTIBLES (IN INCHES)
FIRE HAZARD
. Always maintain published clearances to
combustibles. In locations used for the storage of
combustible materials, signs must be posted. Consult
manual for additional guidelines.
FRONT
SIDE
BEHIND
TOP
BELOW
DANGER
SIDE
SIDE
TOP
BELOW
0° MOUNTING ANGLE
45° MOUNTING ANGLE
FRONT
BEHIND
BELOW
TOP
0° W/1 SIDE SHIELD
BELOW
BEHIND
FRONT
TOP
0° W/2 SIDE SHIELDS
SIDE
SIDE
BELOW
TOP
IMPORTANT:
.
*Use highest BTU output when determining clearances.
Minimum end clearance for all models is 12 inches. Maximum mounting
angle is 45°. Keep cover in place.
LLTCL019-1M-12/18 (CDS)
50,000*
W/1 side shield
W/2 side shields
20 ft. from burner
0°
45°
0°
0°
0°
16
36
33
9
9
MODEL
BTU/H RANGE
MOUNTING
ANGLE
16
9
9
9
9
6
10
6
6
6
43
33
43
46
32
60,000 & 65,000*
W/1 side shield
W/2 side shields
20 ft. from burner
75,000*
W/1 side shield
W/2 side shields
20 ft. from burner
80,000 & 85,000*
W/1 side shield
W/2 side shields
20 ft. from burner
0°
45°
0°
0°
0°
0°
45°
0°
0°
0°
0°
45°
0°
0°
0°
16
36
33
9
9
16
9
9
9
9
6
10
6
6
6
43
33
43
46
32
16
36
33
9
9
16
9
9
9
9
6
10
6
6
6
43
33
43
46
32
16
36
33
9
9
16
9
9
9
9
6
10
6
6
6
43
33
43
46
32
!
WARNING
Improper installation, adjustment,
alteration, service or maintenance
can cause property damage, injury
or death.
Read and understand the installation, operating
and maintenance instructions thoroughly before
installing or servicing this equipment.
12”
This heater must be installed and serviced by trained
gas installation and service personnel only.
This is
NOT
an explosion-proof heater.
DO NOT
install
in explosive environments. Where there is the
possibility of exposure to flammable vapors or dusts,
consult the local fire marshall, your insurance carrier or
authorities for approval of the proposed installation.
VENTING
. This heater must be properly vented
according to the manufacturer’s specifications.
WARNING
: Operation of this heater, when
not properly vented with an approved
system, can result in carbon monoxide
(CO) poisoning and possible death.
This heater requires
FRESH COMBUSTION AIR
for
safe operation and must meet all provisions of the
specified combustion and ventilation requirements.
GAS CONNECTION
. Allowances must be made for the
system to expand. A flexible gas connection of approved
type is required. Flexible stainless steel gas connectors
installed in one plane, without sharp bends, kinks or
twists is recommended. Consult manual for further
instructions.
WARNING
: Connector must be installed in a “C”
configuration. Use only the connector that was
furnished with the heater.
Gas Pipe
Gas Flex
Hose
Gas Flex Hose
Heater
Movement
45°
45°
F/N: LLLOGO32
Logo Label
F/N: LLV3EP2
24 V Input
(Orange crescent
- with relay option)