USER MANUAL
24
DESOI GmbH | Gewerbestraße 16 | D-36148 Kalbach | Phone +49 6655 9636-0 | Fax +49 6655 9636-6666 | [email protected] |
www.desoi.de
GEFAHR! Lebensgefahr!
When working on electrical components, there is a danger to life from electric shock or touch voltage dangerous to
persons.
•
Work on electrical equipment must only be carried out by qualified personnel.
•
Work on the terminal box must not be started until 5 minutes have elapsed due to the presence of touch voltages
(capacitors) which could endanger persons.
•
Check whether all connections (including potential-free contacts) are voltage-free.
•
Before carrying out any work on electrical devices, switch them off and secure them against being switched on
again.
•
Observe the installation and operating instructions of the pump and other accessories!
•
Translated with www.DeepL.com/Translator
CAUTION! Risk of injury due to improper body posture (postural problems)
A healthy posture must be maintained while carrying out any work on the machine.
•
Place the machine in an elevated position for maintenance and repair work, e.g. on a workbench.
7.1 Maintenance and Inspection intervals
NOTE!
If defects are found, they must be corrected by appropriately qualified personnel before the machine is operated
Regular visual inspections and checks:
•
Re-tightening the piston seal
see
point 7.2 (retightening the piston seal)
•
Checking and relubricating the mechanics
see
point 7.3 (relubrication of the mechanics)
•
Testing and retightening of important mechanical
connecting elements
see
point 7.4 (Check/retighten the connecting elements of
the mechanics)
•
Check screw connections
after 2 hours of operation, then every 25 hours of operation
•
Pressure measuring unit
every 40 operating hours for function.
•
Anschlussverbindungen
Check daily at the start of work
•
Material sieve in material container
Check daily at the start of work
•
Defects to be detected externally
Daily when cleaning the machine
•
Elektrische Komponenten auf Beschädigungen
überprüfen
Check daily at the start of work
•
Check the required accessories
Check daily at the start of work
Periodic inspections:
electrical equipment! Every 12 months!!
(Only by a qualified electrician)
•
In accordance with the accident prevention regulation "Electrical installations and equipment" (BGV / GUV-V A3), the
operating company is obliged to ensure that regular retests are carried out.
•
In the instructions for implementing section 5 (1) no. 2 of the Accident Prevention Regulations, examples are given of
guideline values for test intervals that apply under normal operating and environmental conditions. More information about
inspection intervals is provided in the Technical Rules for Industrial Safety "Inspection of work equipment and systems
requiring monitoring" - TRBS 1201.