www.ironhaus.com or www.desatech.com
121334-01A
32
If glass has been broken, carefully remove
glass door (see
Removing/Replacing Glass
Doors
, page 26). Vacuum all glass pieces
with a shop vac.
CAUTION: Do not vacuum if
pieces are hot.
Use only the tempered glass door replace-
ment intended for this fireplace (see
Replace-
ment Parts
, page 37 for detail on ordering). No
substitutions may be made. See
Removing/
Replacing Glass Doors
, page 26 for instruc-
tions for replacing glass door.
WARNING: Do not operate
fireplace with the glass door
unlatched, removed, cracked
or broken.
pILOT AND BURNERS
• Remove ember material before cleaning
burners and replace when cleaning is
complete.
• Burner and controls should be cleaned
with compressed air to remove dust, dirt
or lint.
• Use a vacuum cleaner or small, soft bristled
brush to remove excess dust, dirt or lint.
LOGS
• If you remove logs for cleaning, refer to
Installing Lava Rock and Glowing Embers
,
page 26, to properly replace logs.
• Use a vacuum cleaner to remove any
carbon buildup on logs.
• Replace log(s) if broken. See
Replacement
Parts
on page 37.
•
Replace ember material periodically
as needed. See
Replacement Parts
on
page 37.
VENTING SYSTEM
Conduct annual inspection of the venting
system following these guidelines:
1. Check areas of venting system that are
exposed to the weather for corrosion (rust
spots or streaks and, in extreme cases,
holes). Have these items replaced im-
mediately by a qualified service person.
2. Remove vent cap and shine a flashlight
into vent. Remove any foreign material.
3. Check for evidence of excessive con-
densation. Continuous condensation can
cause corrosion of caps, pipes and fittings
and can be caused by having excessive
lateral runs, too many elbows or exterior
portions of the system being exposed to
cold weather.
4. Inspect joints to verify that no pipe section
or fitting has been disturbed and loos
-
ened. Check mechanical supports such
as wall straps for rigidity.
CLeANING ANd MAINTeNANCe