background image

www.ironhaus.com or www.desatech.com

121334-01A

29

Figure 47 - Setting the Selector Switch, 

Gas Control Knob and Variable Control 

Knob for Remote Operation

oPeRATIoN

Continued

ON/OFF SERIES MODEL HRC100

Hold  the  control  button  on  the  hand-held 
remote  until  burner turns on. Hold  the  con-
trol  button  again  until  burner  turns  off  (see 
Figure 48).

TO LOCK

 press both buttons on hand-held 

remote control until light stops flashing. Hand-
held remote control is now locked. If the fire 

is on it will be turned off automatically. In the 
locked state, the light will not light up when 
any button is pressed.

TO  UNLOCK

  press  both  buttons  together 

on  hand-held  remote  control  until  the  light 

stops flashing. The hand-held remote is now 

unlocked.

THERMOSTAT SERIES MODEL HRC200

The hand-held remote can be operated using 
either the manual mode (MANU) or thermo-
static mode (AUTO) (see Figure 49). To select 
Fahrenheit/Centigrade mode display, carefully 

press the ˚C/˚F mode button with the end of a 

paper clip or similar blunt object.

Manual Mode

1.  Press  the  POWER  and  LOCK  buttons 

together to turn on the hand-held remote 
control.

2.  Press  the  MANU  button  to  turn  on  the 

fireplace.

3.  Press  the  POWER  and  LOCK  buttons 

together to turn off the fireplace.

Auto (Thermostatic) Mode

1.  Press  the  POWER  and  LOCK  buttons 

together to turn on the hand-held remote 
control.

2.  Press AUTO button to select this mode.
3.  Set  the  desired  room  temperature  by 

pressing the TEMP + or - buttons.

4.  Press  the  POWER  and  LOCK  buttons 

together to turn off the fireplace

Note: Do not leave the hand-held remote in the 

AUTO mode close to the fireplace. The radiant 
heat from the fireplace will turn off the fireplace. 

Ideally, place the hand-held remote in the center 

of the room facing towards the fireplace.

Note: Do not hold the hand-held remote for 
a long time. Body temperature will affect its 
operation in the AUTO mode.

Safety Features

When away from home for an extended period 
of time or as a child safety feature to prevent 

accidental ignition of the fireplace, the receiver 

ON/OFF/REMOTE  switch  should  be  in  the 
OFF position.

Auto Shutoff Feature

1.  If the average room temperature reaches 

a range of 82° F (28° C), the hand-held 
remote control will perform a safety over-

ride and shut the fireplace off. This feature 

is not available in the MANU mode.

OF

F   

PIL

O

T

  

 

L

O

 

IH

 

ON

OFF

REMOTE

ON

OFF

O

N  

    

      

    

Blower Control Knob 
(Optional Accessory)

Variable Control 
Knob

Selector Switch in 
Remote Position

Gas Control Knob 
in ON Position 

Figure 48 - On/Off Hand-Held Remote 

Control Unit HRC100

Control 
Button

Indicator 
Light

Figure 49 - Thermostat Hand-Held 

Remote Control Unit HRC200

LOCK

MANU

AUTO

ºC/ºF

TEMP

POWER

ROOM
TEMP

SET
TEMP

AUTO

Turns 
Hand-Held 
Remote On 
or Off and 
Allows You 
to Choose 
the Manual 
Setting

Selects 
AUTO 
Mode

°C/°F Mode 
Button

Locks 
System to 
Prevent 
Accidental 
Ignition

Turns 
Burners 
On or Off

Increases or 
Decreases 
Room 
Temperature in 
AUTO Mode

Digital Display Shows 
Temperature and Settings

Содержание IRONHAUS IKC42N Series

Страница 1: ...al switch do not use any phone in your building Immediatelycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied installer service agency or the gas supplier INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future referenc...

Страница 2: ...ler and or shipper immediately if damaged and document with photos etc 2 Remove glass or mesh door s from the frame and set aside in a safe place throughout the construction process 3 Reinstall the glass or mesh door s 4 Follow guidelines in this installation manual Further helpful information can be found for framing dimensions and other technical specifications at either www desatech com or www ...

Страница 3: ... properly Get fresh air at once Have fireplace serviced Some people are more af fected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influ ence of alcohol and those at high altitudes Safety Continued Natural and Propane LP Gas Natural and propane LP gas are odorless An odor making agent is added to the gas The odor helps you...

Страница 4: ...nly a qualified service person should install service or re pair this fireplace Have fireplace inspected annually by a qualified service person 5 You must keep control compartments burners and circulating air passages clean More frequent cleaning may be needed due to excessive lint and dust from carpeting bedding material etc Turn off the gas valve and pilot light before cleaning fireplace 6 Have ...

Страница 5: ... Only the blower requires electricity if in stalled and if you plan to install the blower at a later date do not forget to wire the outlet at the bottom of the fireplace when framing A piezo ignitor and ceramic electrode cre ate spark to ignite the pilot light It does not require any matches batteries or any other sources of ignition to light the pilot Each time you turn on your fireplace you may ...

Страница 6: ...these spacers can be placed directly against wall or framing material See framing details on page 7 If you plan on installing a television or enter tainment center recessed above your fire place it is recommended that you maintain a minimum 18 above top of louver opening When locating termination cap it is impor tant to observe the minimum clearances shown in Figure 7 page 8 If recessing into a wa...

Страница 7: ...for use as supplemental heat Use this fireplace along with your primary heating sys tem Do not install this fireplace as your primary heat source If you have a central heating system you may run system s circulating blower while using fireplace Thiswillhelpcirculate the heat throughout the house In the event of a power outage you can use this fireplace as a heat source Framing and finishing Figure...

Страница 8: ...2 30 cm in US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally L clearance above paved side walk or a paved driveway located on public property 84 213 3 cm minimum M clearance under veranda porch deck 12 30 5 cm minimum N clearance above a roof shall ex...

Страница 9: ...must terminate on the out side of the structure and can not be attached to a chimney or flue system serving a separate solid fuel or gas burning appliance Adirect vent appliance must have its own venting system DO NOT common vent this appliance These models are approved to be vented either horizontally through an outside wall or vertically through a roof or chase enclosure using the following guid...

Страница 10: ...ing slots on male ends of adjacent pipes Push pipe sections together and twist one section clockwise approximately one quarter turn until the sections are fully locked see Figure 8 Note Horizontal runs of vent must be sup ported every three feet Use wall straps for this purpose 3 Use a 45 elbow to connect venting sys tem to fireplace flue collar The elbow is designed to be twist locked onto flue c...

Страница 11: ... with wood screws provided see Figure 11 Siding standoff must sit flush against exterior fascia material 7 Connecting Vent Cap with Horizontal Vent Pipe Slide wall firestop over vent pipe before connecting horizontal run to vent cap see Figure 12 Carefully move fireplace with vent as sembly attached toward wall and insert vent pipe into horizontal termination Pipe overlap should be a minimum of 11...

Страница 12: ...ion is required NOTICE Donotsealtermination cap to vent pipe Cap must be removable for vent inspection and maintenance WARNING Never run vent downward as this may cause excessive temperatures which could cause a fire Operation of improperly installed and main tained venting system could result in serious injury property damage or loss of life GROUND FLOOR INSTALLATION Recommended Applications Inst...

Страница 13: ...ALLATION Recommended Applications Installations requiring a vertical rise on building exterior Any installation using snorkel termination to achieve one foot above ground Snorkel terminations are available for installations requiring a vertical rise on the exterior of the building If installing snorkel termination below grade you must provide proper drainage to prevent water from entering snorkel ...

Страница 14: ...uirements for a horizontal system using two 90 elbows Figure 18 Horizontal Termination Configuration for Venting Using Two 90 Elbows with Termination at 90 with Fireplace 45 Elbow Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H1 Horizontal H2 5 min 2 max 6 max 6 min 4 max 12 max 7 min 6 max 18 max 8 min 8 max 20 max 20 max 8 max 20 max Venting with Two 90 Elbows Vertical V Horizon...

Страница 15: ...s If area above ceiling is an insulated ceiling or an attic nail firestop from top side This prevents loose insula tion from falling into required clearance space If area above ceiling is a living space install firestop below framed hole Firestop should be installed with no less than three nails per side see Figure 20 2 Assemble the desired lengths of pipe and elbows necessary to reach from firepl...

Страница 16: ...ical Round High Wind Termination Shown 45 Elbow Venting with Two 90 Elbows Vertical V Horizontal H1 Horizontal H2 5 min 2 max 6 min 4 max 7 min 6 max 8 min 8 max 20 max 8 max Note Install restrictor into inner collar of fireplace as shown Venting with One 90 Elbow Vertical V Horizontal H 5 min 2 max 6 min 4 max 7 min 6 max 8 min 8 max 20 max 8 max Note Install restrictor into inner collar of firep...

Страница 17: ...ireplaces for High Altitude models ending in HA are for installation above 4000 feet only These fireplaces are equipped with parts specific for higher altitudes When installing a non high altitude fireplace at an elevation above 2000 feet in the USA you may need to decrease the input rating Venting with Two 90 Elbows Vertical V1 Horizontal H 5 min 6 max 6 min 12 max 7 min 18 max 8 min 20 max by ch...

Страница 18: ...Storm Collar Roof Flashing 0 12 6 12 26 Screws VKC 58 Corner Vent Kit Galvanized Includes 45 Elbow 7 12 Adjustable Pipe Wall Firestop Horizontal Termination 6 Pipe 90 Elbow 18 Screws HHTK 58 High Wind Round Horizontal Termination Kit Includes Round Termination Wall Firestop 45 Elbow HHT 58 High Wind Round Horizontal Termination Kit Galvanized HTS 58 Horizontal Square Termination Galvanized HTKS 58...

Страница 19: ...rt directed upward Blower will fit inside back opening and be held in position against back wall by magnets see Figure 26 4 Be certain that all wire terminals are securely attached to terminals on blower motor and that screw retaining green ground wire is tight Blower Location Side View Figure 26 Blower Model BK Magnetic Strips Exhaust Port Screw Green Ground Wire Spade Terminals Lower Firebox Cav...

Страница 20: ...al Note Power cord outer insulation sleeve may have to be stripped slightly to allow enough wire length to reach and make all connec tions DO NOT trim excessive length away Enable just enough to make all connections securely 3 Place blower against lower rear wall of firebox outer wrapper with exhaust port di rected upward and thermodisc positioned up near fireplace bottom Thermodisc must be orient...

Страница 21: ... Fan Switch Fan Switch N O Green White On 110 115 V A C Blower Motor Black Off 1 2 Black Installing Gas Piping to Fireplace Location WARNING A qualified service person must connect fireplace to gas supply Follow all local codes CAUTION For propane LP units never connect fireplace directly to the propane LPsupply This heater requires an external regulator not supplied Install theexternalregulatorbe...

Страница 22: ... a sediment trap drip leg in supply line as shown in Figure 32 Locate sediment trap drip leg where it is within reach for cleaning Install in piping sys tem between fuel supply and fireplace Locate sediment trap drip leg where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into fireplace gas controls If sedi ment trap drip leg is n...

Страница 23: ...ropane LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air 4 Check all joints of gas supply piping sys tem Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once 5 Reconnect fireplace and equipment shutoff valve to gas supply Check recon nected fittings for leaks Test Pressure...

Страница 24: ...If wires are not connected as shown switch will not work 2 Route 25 ft wire through openings pro vided on sides of burner system to a con venient location to mount your switch 3 Connect one bare wire end to each termi nal of the GWMS2 wall switch 4 Install wall switch and cover in the wall Fireplace Installation Continued Figure 37 Connecting Wall Switch to Control Valve To Wall Switch Accessory I...

Страница 25: ... or removing broken glass Do not remove if glass is hot Keep children and pets away from glass WARNING If fireplace has been running turn off and un plug fireplace Let cool before removing inner glass door or louvers Removing Louver Panels Remove top and bottom louver panels by simultaneously pulling both top end spring latches towards center of appliance until they are disengaged from locating ho...

Страница 26: ...r Material on Burner Ember Material Plenum Andiron Removing Inner Glass Door If replacement of glass is necessary entire assembly glass and frame must be replaced If glass is broken wear gloves and tape re maining fragments onto frame 1 Lift up on latches to unlock There are two on top of firebox and two below firebox that hold glass door in place see Figure 43 2 While holding glass door to preven...

Страница 27: ...p 6 replace plenum and attach to burner 13 Carefully replace the ember pod and log set 14 Use screws removed in step 4 to replace andiron assembly 15 Install lava rock and glowing embers See Installing Lava Rock and Glowing Embers page 26 16 Close glass door and lock latches on top and bottom of door and replace screen See Removing Inner Glass Door steps 5 and 6 page 26 17 Replace top and bottom l...

Страница 28: ... PILOT LO IH O N Figure 46 Control Valve Piezo Ignitor Gas Control Knob Variable Control Knob 12 To leave pilot lit and shut off burners only turn control knob clockwise to the PILOT position or set selector switch in the OFF position 13 Close lower louver panel TO TURN OFF GAS TO APPLIANCE 1 Open lower louver panel 2 Set selector switch in the OFF position to prevent draining battery 3 Turn off a...

Страница 29: ... Set the desired room temperature by pressing the TEMP or buttons 4 Press the POWER and LOCK buttons together to turn off the fireplace Note Do not leave the hand held remote in the AUTO mode close to the fireplace The radiant heat from the fireplace will turn off the fireplace Ideally place the hand held remote in the center of the room facing towards the fireplace Note Do not hold the hand held ...

Страница 30: ...tional blower accessory Locate blower controls by opening lower louver panel on fireplace Blower controls are located on right side of switch bracket to the left just inside louver panel The BK manual blower and BKT thermostat ically controlled blower have an ON setting and an OFF setting Blower will only run when switch is in the ON position In the OFF posi tion blower will not operate Note for B...

Страница 31: ...s of operation Thereafter clean the glass two or three times during each heating season depending on the usage and circumstances present Refer to Removing Replacing Glass Doors page 26 of this manual when removing inner glass door for cleaning WARNING Only parts sup pliedbythemanufacturershould be used when replacing broken or damaged glass door panel see Replacement Parts page 37 This glass door ...

Страница 32: ...er to Installing Lava Rock and Glowing Embers page 26 to properly replace logs Use a vacuum cleaner to remove any carbon buildup on logs Replace log s if broken See Replacement Parts on page 37 Replace ember material periodically as needed See Replacement Parts on page 37 Venting system Conduct annual inspection of the venting system following these guidelines 1 Check areas of venting system that ...

Страница 33: ... lines when in stalled 5 Depleted gas supply pro pane LP models only 6 Pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Tighten nut holding piezo ignitor Nut is located be hind the mounting bracket 4 Replace ignitor cable 5 Replace piezo ignitor 6 Replace pilot assembly 7 Tighten...

Страница 34: ...l gas company 2 Clean burner see Clean ing and Maintenance page 31 or replace burner orifice 1 Clean burner see Clean ing and Maintenance page 31 or replace burner orifice 2 Replace damaged burner 3 Replace gas control 1 Problem will stop after a few hours of operation TROUBLESHOOTING Continued POSSIBLE CAUSE 1 Gas control knob not fully pressed in 2 Gas control knob not pressed in long enough 3 E...

Страница 35: ...ge 26 for log grate removal 2 Check vent configuration specifications see Venting Installation page 9 1 This is normal If noise is excessive contact qualified service person 1 Replace 9 volt batteries in receiver and remote control 1 Clean out air holes at burner inlets Periodically repeat as needed 2 Remove blockage or re place burner 3 Have vent system inspect ed including termination cap Remove...

Страница 36: ...ion 1 Gas leak See Warning statement above 2 Control valve defective 1 Gas leak See Warning statement above OBSERVED PROBLEM Fireplace produces un wanted odors Fireplace shuts off in use Gas odor even when control knob is in OFF position Gas odor during combustion REMEDY 1 Locate and correct all leaks see Checking Gas Connec tions page 23 1 Fireplace has been tested for up to 40mph winds However e...

Страница 37: ...f this product If they can t supply original replacement part s call DESA Heating LLC at 1 866 672 6040 When calling DESA Heating LLC have ready your name your address model and serial numbers of your heater how heater was malfunctioning purchase date Usually we will ask you to return the part to the factory Parts Not Under Warranty Contact authorized dealers of this product If they can t supply o...

Страница 38: ...www ironhaus com or www desatech com 121334 01A 38 Parts Models IKC42N Series 6 7 20 17 18 13 2 12 19 8 1 4 24 11 9 14 3 16 5 15 21 10 23 25 26 22 ...

Страница 39: ...331 02 Bottom Louver Assembly 1 6 Fireplace Top 1 7 Fireplace Top Insulation 1 8 Fireplace Surround 1 9 109082 01 Heat Shield 1 10 116542 01 Burner Assembly NG See page 40 1 116211 05 Burner Assembly for High Altitude Models See page 40 1 11 See Below Left Refractory Brick Panel 1 12 See Below Rear Refractory Brick Panel 1 13 See Below Right Refractory Brick Panel 1 14 111874 03 Andiron Assembly 1...

Страница 40: ...www ironhaus com or www desatech com 121334 01A 40 PARTS Burner assembly models IKC42N Series 7 15 10 12 1 12 2 3 13 9 11 21 22 TPTH TP TH 6 12 14 18 17 17 18 19 20 16 14 8 4 5 ...

Страница 41: ... 3 8 Zinc 2 8 116572 02 Tubing Assembly 1 9 111288 02 Flex Gas Line 1 10 108084 02 Pilot Assembly NG 1 108084 05 Pilot Assembly HA Models 1 11 14389 Natural Gas Valve 1 117370 01 Natural Gas High Altitude Valve 1 12 11165 Screw 10 x 5 8 Zinc 23 13 111913 02 Burner Base Gasket 1 14 14396 Brass Fitting 2 15 116345 01 Pilot Bracket 1 16 26827 Switch Bracket 1 17 116573 01 Flat Washer 7 8 ID x 2 OD 2 ...

Страница 42: ...ded in this manual Flexible gas Line connector CIK For all models Propane natural gas conversion kit IMPORTANT NOT to be used for High Alti tude HA Models PCDM 42KC Propane LP Gas Conver sion Kit Face Louver Filigree Panel kit FPD42 Black FPD42B Brushed Brass FPD42P Platinum FPD42PB Polished Brass Rolled Louver trim kit LT42B Brushed Brass LT42P Platinum LT42PB Polished Brass Deflection hoods HD42...

Страница 43: ...chase Transit damage and results from alterations are not covered by this warranty IRONHAUS disclaims all other warranties whether expressed or implied and specifically disclaims the implied warranties of merchantability and fitness for a particular purpose In no event shall IRONHAUS be liable to customer or user in warranty contract negligence strict liability or otherwise for any damages whether...

Страница 44: ...pproved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material labor and incidental costs associated with warranty repairs unless expressly covered by this warran...

Отзывы: