63
10.2 Commands
10.2.1 Waiting for input
Waits for an input
Switching to the next stage takes place as soon as the input is present.
Parameter:
• Maximum waiting time
• Input number
10.2.2 Setting the output
Sets an output.
Parameter:
• Output number
• Time monitoring: yes / no
If time monitoring is switched on or enabled, the following parameter is also required:
o
Time until reset
10.2.3 Resetting the output
Resets an output.
Parameter:
• Output number
10.2.4 Display Values
Displays the values of the previous screwing level at the touch display. The command can
used as often as you like.
10.2.5 Save Values
Saves the values of the previous screwing level into the end value data set. The command
can be used as often as you like (also see
).
IMPORTANT
As a maximum the last three results are saved.
10.2.6 Statistic
Affects the calculation of the statistic of the previous screw level (also see
).
IMPORTANT
The statistic can only be calculated for a screwing level per program. If
the 'statistic' command is entered more than once into the program then
only the statistic for the last screwing level is calculated, for which the
'statistic' command has been indicated.
10.2.7 Waiting Time
Inserts a waiting time into the program.
Parameter:
• Waiting time
10.2.8 Hold Position
Affects the holding of the current position
Parameter:
• Holding time