52
9.2 Default
Values
The default values can be adjusted as follows:
• at the control in the system menu
tab the setting on the general page to "set
default values"
• click the "reset" button in the web interface in the setting menu
default settings
9.2.1 General
Parameters
Parameter
Value
Language english
Unit for torque
N•cm
Main direction of rotation
right
Password 0000
Baud rate
auto
Rotation speed decrease
active
Signal sound
never
Offset gear
Gear transmission ratio
1
Efficiency 100%
Direction change
no
Fieldbus
Available no
Control via I/O interface
inactive
Statistic: Limits for CP/CPK value
+/- 15%
Table 12:
Default Values
9.2.2 Special parameters for fieldbus systems (optional)
9.2.2.1 Profibus
Parameter
Value
Profibus address
64
Table 13:
Default values for Profibus
9.2.2.2 Profinet
Parameter
Value
IP address
10.10.24.10
Net mask
255.255.00
Gateway 10.10.20.9
Station name
nic 50 repns
Table 14:
Default values for Profinet
9.2.2.3 Ethernet
IP
Parameter
Value
IP address
10.10.24.11
Net mask
255.255.0.0
Gateway 10.10.20.9
DHCP inactive
BOOTP inactive
Table 15:
Default values for Ethernet IP
9.2.2.4 Ethercat
No settings are necessary.