12.3 Statistic
If the command "statistic" is used in the screwing program then in the sequence controller
AST6 a statistic is kept about the last 100 values for the respective program.
The following values are calculated for moment and angle:
• Mean value
• Standard deviation absolute
• Standard deviation percentages, based on mean value
• CP value / CPK value
The limits for the Cp/CPK value calculation can be entered. If no limits are set then the
calculation is done automatically with ±15% of the mean value. The limits entered are
maintained even after switching off the sequence controller AST6.
The statistic can be displayed via the sequence controller AST6 as well as via the web
interface (also see
). The statistic can be deleted for individual
programs or completely for all programs.
The statistic is deleted when the sequence controller AST6 is switched off.