4.4. All servo on and Auto Adjustment
When "
Cursor
u
" button is pressed, all servos turn on, auto adjustment is performed and switch to playback operation.
(Playback sound output)
Stopn(stopntonthenplaybacknstatenafternautonadjustment)n
When "
SOURCE
" button is pressed, play operation and servo stop. The following will be displayed.
After stopping, conduct reading of auto adjust values.
Adjustmentnvaluendisplayn(AfternAllnServononnandnAutonAdjustment)
Press the "
SOURCE
" button, after All servo on and Auto Adjustment.
When "
Cursor
u
/
i
" button is pressed, the adjustment values are displayed in the following order.
q
FOCUS BALANCE
w
FOCUS GAIN
e
TRACKING BALANCE
r
TRACKING GAIN
t
FOCUS OFFSET
y
TRACKING OFFSET
u
RFRP
(Caution) If you have not completed the adjustment, the value is not correct.
4.5. Laser current display
When "
VOLUME
d
" button is pressed for over 1 second while the Unit is in the CD TEST MODE, the laser turns on and the
laser current is measured.
The voltage when the laser is on and off is measured (converted to A/D) and the current is calculated from this. The deci-
mal point is omitted.
The current value is updated every 3 seconds.
Press the "
SOURCE
" button, CD TEST MODE display reappears.
Stored data is not cleared, even when the Unit is reset(Factory/User).
Overwritingnthenstoredndata
When the "
1
/
3
" button is pressed for over 5 seconds while the laser current is displayed, the current value is stored in the
EEPROM (overwriting the stored data).
Once rewriting is completed, the display in "Laser current display" reappears. Rewriting is performed upon shipment from
the factory and when the mechanism is replaced.