Initializing This Unit
Initialize this unit if you have replaced the microcomputer, one of the parts around the microcomputer, or the digital PCB.
1. In "
STANDBY
" status, press and hold the "
CURSOR
u
" and "
INPUT SOURCE
" buttons along with the power opera-
tion button to turn on the power. Factory Initialization Mode
JIG FOR SERVICING
Measuring Disc:
CD/TCD-784
CD-R/TCD-R082W
CD-RW/TCD-W082W
z
See "MEASURING METHOD AND WAVEFORMS".
Procedure after Replacing the WLAN MODULE
When replaced of the WLAN MODULE(CY920-C), confirm contents of the following.
Caution
WLAN MODULE and NFC MODULE are supplied in a set so that the BT ADDRESS matches.
If one module is faulty, replace the entire set.
(1) When replacing the WLAN MODULE, use the "Part No." corresponding to your region in the table below.
MODULE Name
Remarks
Part No.
CY920 MODULE ASSY
E2 / JP
943189101050D
(2) Update the firmware using a USB flash drive.
(See 31 page)
(3) When replacing the modules, replace the MAC address label on the bottom of the unit with the new one.
NOTE
:
nnn
Initializing the device restores settings configured by the user to the factory settings. Take note of your set-
tings beforehand and reconfigure them after initialization.