DAEnetIP3
User Manual
-
77
-
(PortA.0)
up to F
(PortA.15)
?
– read value
up to 99
OFF
parameter.
Value is from 0
to 99.
OFF parameter in 2
answer:
AF0=10;
command:
AFC=?;
„Get
PortA.12 ON parameter.
answer:
AFC=10; „10
AD
From 0
(PortA.0)
up to F
(PortA.15)
From 0 up to 99,
?
– read value
From 00
up to 99
Set/get the
Delay
parameter.
Value is from 0
to 99.
command
:
AD1=5; „Set PortA.1
Delay parameter in 5
answer:
AD1=5;
command:
ADC=?; „Get
PortA.12 Delay parameter.
answer:
ADC=10; „10
A1
From 0
(PortA.0)
up to F
(PortA.15)
From 00:00:00 up
to 23:59:59,
?
– read value
From
00:00:0
0 up to
23:59:5
9
Set/get the
Time1
parameter.
The time value
must be in
format
HH:MM:SS
command
:
A11=12:00:00; „Set
PortA.1 Time1 event at 12
o‟clock
answer:
A11=12:00:00;
command:
A11=?; „Get PortA.1
Time1 parameter.
answer:
A11=01:00:30
A2
From 0
(PortA.0)
up to F
(PortA.15)
From 00:00:00 up
to 23:59:59,
?
– read value
From
00:00:0
0 up to
23:59:5
9
Set/get the
Time2
parameter.
The time value
must be in
format
HH:MM:SS
command
:
A21=12:00:00; „Set
PortA.1 Time1 event at 12
o‟clock
answer:
A21=12:00:00;
command:
A21=?; „Get PortA.1
Time2 parameter.
answer:
A21=01:00:30
AC
From 0
(PortA.0)
up to F
(PortA.15)
Max 10 symbols
'a'-'z', 'A'-'Z', '0'-'9',
'_' and '.',
?
– read value
Descript
ion
string
Set/get the
Description
parameter.
command
:
AC1=DO1; „Set
PortA.1 description DO1
answer:
AC1=DO0;
command:
ACC=?; „Get
PortA.12 description.
answer:
ACC=DO12;
AT
From 0
(PortA.0)
up to F
(PortA.15)
0
– seconds,
1
– minutes,
2
– hours,
?
– read value
0,1 or 2
Set/get the
timer/delays
resolution for
this channel.
(2.0.0 version)
command
:
AT1=0; „Set PortA.1
resolution in seconds
answer:
AT1=0;
command:
ATC
=?; „Get
PortA.12 resolution.
answer:
ATC=2; 'hours