DAEnetIP3
User Manual
-
29
-
Figure 10.
Timer requests
This mode (figure 25) allows the given digital output mode to make single (one-
shoot) pulse with custom delay. The pulse can not be stopped, only can be started. If
the current pulse is started and not elapsed and new request for single pulse is
appeared then the pulse will be stopped after the delay time after the last pulse is
started (figure 26). The reason for this is that the DAEnetIP3 controller accepts that
the last received request for single pulse is with highest priority. The user can not
control manually the outputs in this mode.
7.5.17.
Timer and digital input
This mode (figure 27) configures the digital output to work as single pulse
generator based on digital input falling/rising slope. Because the pulse can not be
stopped, it can be only started during falling/rising slope depending on the mode in
which the digital input works in. Note that if the time between two falling (rising)
slopes is less than the delay of the single pulse, the digital output level will be in 1
until this interval became greater than Timer delay. The user can not control
manually the outputs in this mode.