67
Parameter Read Command
"R,S,A,UU,NN"
COMPUTER TO AC MOTOR DRIV
COMMAND STRUCTURE
Word length = 7 characters
R: Header of read string
S:
Check sum (03H)
A: Command
acknowledge
01H: Command acknowledged by a single AC drive
02H: Command acknowledged by all AC drives
UU: Slave address (“00” - “31”)
NN: Parameter number (“00” “80”)
The AC drive will return a character string, the format of which will be as follows:
"R,S,B,UU,NN,DDDD"
AC MOTOR DRIVE TO COMPUTE
COMMAND STRUCTURE
Word length = 11 characters
R: Header of read string
S:
Check sum (03H)
B: Acknowledge
back
Correct:
06H
Error: 07H
UU: Slave address (“00” - “31”)
NN: Parameter number (“00” “80”)
DDDD: Data of parameter
AC drive Status Read Command
"Q,S,A,UU,NN"
COMPUTER TO AC MOTOR DRIV
COMMAND STRUCTURE
Word length = 7 characters
Q: Header of question string
S:
Check sum (03H)
A: Command
acknowledge
01H: Command acknowledged by a single AC drive
02H: Command acknowledged by all AC drives
UU: Slave address (“00” - “31”)
NN: Retrieve contents of drive status. (x = don‘t care)
X0:
Frequency
command
X1:
Output
frequency
X2:
Output
current
X3: Operation command Drive status and Error code
Содержание VFD-A
Страница 1: ......
Страница 2: ...5011200503 200305 22 AE02...
Страница 3: ......
Страница 65: ...61 APPENDIX A Standard Specifications...
Страница 77: ...73 Remote Controller RC01 Adapter Unit mm inches Standard Extension Cable Unit mm...
Страница 79: ...75 Braking Resistors Braking Units Braking Resistors Braking Units...
Страница 80: ...76 Braking resistors model no BR1K0W050 BR1K2W008 BR1K2W6P8 BR1K5W005 BR1K5W040...