11
Connect the probes. Turn on the instrument: after about 10 seconds, the measurements will appear
on the display:
HD37AB1347
2010/02/10 08:00:00
Carbon Dioxide
CO
2
ppm
600
CO 0 ppm
RH 25.0 %
T1 17.0 °C
Patm 1000 hPa
Va 0.00 m/s
CO
2
:
Carbon Dioxide
CO:
Carbon Monoxide
RH:
Relative Humidity
T1:
Temperature detected by the probe connected to input 1
Patm:
Atmospheric
Pressure
Va:
Wind
Speed
3.1.1 “
►
/UNIT” key for the unit of measurement
It
allows navigation through the menus. During normal operation, it changes the unit of
measurement of the
main quantity
:
If the
main quantity
is Relative Humidity, by repeatedly pressing the UNIT key you can display
the following quantities:
RH
Relative Humidity (%)
Td
Dew Point (°C - °F)
AH
Absolute Humidity (g/m
3
)
r
Mixing Ratio (g/kg)
Tw
Wet Bulb Temperature (°C - °F)
H
Enthalpy (kJ/kg)
If the
main quantity
is Temperature, by repeatedly pressing the UNIT key you can display the
temperature in °C (Celsius degrees) or °F (Fahrenheit degrees).
If the
main quantity
is Wind Speed, by repeatedly pressing the UNIT key you can display the
Wind Speed in m/s – km/h – ft/min – mph – knot.
If the
main quantity
is Flow Rate, by repeatedly pressing the UNIT key you can display the Flow
Rate in L/s – m
3
/s – m
3
/min – m
3
/h – ft
3
/s – ft
3
/min.
Содержание HD37AB1347