Chapter 4 Parameters
|
4-44
Revision Dec. 2008, 04VE, SW V2.05
Pr.
Explanation
Settings
Factory
Setting
VF VFPG SVC FOCPG TQCPG
0: Disable
0
○
○
○
○
08-21
Tension Control
Selection
1: Tension closed-loop, speed mode
○
○
○
○
2: Line speed closed-loop, speed mode
○
○
○
○
3:
Reserved
4: Tension open-loop, torque mode
○
08-22
Wind Mode
0: Rewind
1: Unwind
0
○
○
○
○
○
08-23
Mechanical Gear A
at Reel
1-65535 100
○
○
○
○
○
08-24
Mechanical Gear B
at Motor
1-65535 100
○
○
○
○
○
08-29
Proportional Gain 1
of Tension PID P
0.0~1000.0 50.0
○
○
○
○
08-30
Integral Time of
Tension PID I
0.00~500.00 sec
1.00
○
○
○
○
08-32
Proportional Gain 2
of Tension PID P
0.0~1000.0 50.0
○
○
○
○
08-33
Integral Time 2 of
Tension PID I
0.00~500.00 sec
1.00
○
○
○
○
08-36
Tension/Line Speed
PID Output Limit
0~100.00%
20.00
○
○
○
○
08-40
Pulse Number for
Each Meter
0.0~6000.0 pulse/m
0.0
○
○
○
○
○
08-41
Current Line Speed
0.0~3000.0m/min
0.0
○
○
○
○
○
08-46
Initial Reel Diameter
0.0~6000.0mm
1.0
○
○
○
○
○
08-47
Initial Reel Diameter 1
0.0~6000.0mm
1.0
○
○
○
○
○
08-48
Initial Reel Diameter 2
0.0~6000.0mm
1.0
○
○
○
○
○
08-55
Smart Start Function
0: Disable
1: Enable
2: In unwind mode, rewind in reverse direction
1
○
○
○
○
08-61
Allowance
Difference of Reel
Diameter of Broken
Belt Detection
1.0~6000.0mm 100.0
○
○
○
○
08-64
Allowance Error
Detection Time of
Tension/Line Speed
PID Feedback
0.0~10.0 sec
0.5
○
○
○
○
08-65
Error Treatment of
Tension/Line Speed
PID Feedback
0: Warn and keep operation
1: Warn and coast to stop
2: Warn and ramp to stop
0
○
○
○
○
Group 9 Communication Parameters
Pr.
Explanation
Settings
Factory
Setting
VF VFPG SVC FOCPG TQCPG
09-22
Display Digital Value
of Analog Output 2
0~4095 Read-
only
○
○
○
○
○
09-23
Display Digital Value
of Analog Output 3
0~4095 Read-
only
○
○
○
○
○
Group 10 Speed Feedback Control Parameters
Pr.
Explanation
Settings
Factory
Setting
VF VFPG SVC FOCPG TQCPG
10-02
Encoder
Feedback
Fault Treatment
0: Warn and keep operation
1: Warn and ramp to stop
2: Warn and coast to stop
2
○
○
○
10-03
Detection Time for
Encoder
Feedback
Fault
0.00~10.0 sec
1.0
○
○
○
10-04
ASR (Auto Speed
Regulation) Control
( P) 1
0~40 10
○
○
○
10-05
ASR (Auto Speed
Regulation) Control (I)
0.000~10.000 sec
0.100
○
○
○
CALL NOW 800-985-6929
http://www.automatedpt.com
CALL NOW 800-985-6929
http://www.automatedpt.com
Содержание VFD-VE
Страница 1: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...
Страница 2: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...
Страница 3: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...
Страница 39: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...