Chapter 4 Parameters
|
4-40
Revision Dec. 2008, 04VE, SW V2.05
Pr.
Explanation
Settings
Factory
Setting
VF VFPG SVC FOCPG TQCPG
49: Enable Drive
○
○
○
○
○
50:
Reserved
0: No function
11
○
○
○
○
○
02-11
Multi-function Output 1
RA, RB, RC(Relay1)
1: Operation indication
○
○
○
○
○
2: Operation speed attained
1
○
○
○
○
○
02-12
Multi-function Output 2
MRA, MRC (Relay2)
3: Desired frequency attained 1 (Pr.02-19)
○
○
○
○
○
4: Desired frequency attained 2 (Pr.02-21)
0
○
○
○
○
5: Zero speed (frequency command)
○
○
○
○
02-13
Multi-function Output 3
(MO1)
6: Zero speed with stop (frequency command)
○
○
○
○
7: Over torque (OT1) (Pr.06-06~06-08)
○
○
○
○
○
8: Over torque (OT2) (Pr.06-09~06-11)
○
○
○
○
○
9: Drive ready
0
○
○
○
○
○
02-14
Multi-function Output 4
(MO2)
10: User-defined Low-voltage Detection
○
○
○
○
○
11:
Malfunction
indication
○
○
○
○
○
12: Mechanical brake release (Pr.02-31)
○
○
○
○
○
02-35
Multi-function Output 5
(MO3)
13: Overheat
○
○
○
○
○
14: Software brake signal indication
○
○
○
○
○
15: PID feedback error
○
○
○
○
○
02-36
Multi-function Output 6
(MO4)
16: Slip error (oSL)
○
○
○
○
17: Terminal count value attained (Pr.02-16)
○
○
○
○
○
18: Preliminary count value attained (Pr.02-17)
○
○
○
○
○
02-37
Multi-function Output 7
(MO5)
19: Baseblock (B.B.) Indication
○
○
○
○
○
20:
Warning
output
○
○
○
○
○
21: Over voltage warning
○
○
○
○
○
02-38
Multi-function Output 8
(MO6)
22: Over-current stall prevention warning
○
○
○
○
○
23: Over-voltage stall prevention warning
○
○
○
24: Operation mode indication
○
○
○
○
○
02-39
Multi-function Output 9
(MO7)
25: Forward command
○
○
○
○
26: Reverse command
○
○
○
○
27: Output when current >= Pr.02-32
○
○
○
○
○
02-40
Multi-function Output 10
(MO8)
28: Output when current < Pr.02-32
○
○
○
○
○
29: Output when frequency >= Pr.02-33
○
○
○
○
○
30: Output when frequency < Pr.02-33
○
○
○
○
○
02-41
Multi-function Output 11
(MO9)
31: Y-connection for the motor coil
○
○
○
○
32:
Δ
connection for the motor coil
○
○
○
○
33: Zero speed (actual output frequency)
○
○
○
○
02-42
Multi-function Output 12
(MOA)
34: Zero speed with Stop (actual output frequency)
○
○
○
○
35: Error output selection 1 (Pr.06-23)
○
○
○
○
○
36: Error output selection 2 (Pr.06-24)
○
○
○
○
○
37: Error output selection 3 (Pr.06-25)
○
○
○
○
○
38: Error output selection 4 (Pr.06-26)
○
○
○
○
○
39: Position attained (Pr.10-19)
○
40: Speed attained (including zero speed)
○
○
○
○
41: Multi-position attained
○
42: Crane function
○
○
○
○
43: Motor zero-speed output (Pr.02-43)
○
○
44: Max. reel diameter attained
○
○
○
○
○
45: Empty reel diameter attained
○
○
○
○
○
46: Broken belt detection
○
○
○
○
○
47: Break release at stop
○
○
○
○
48: Error PID feedback of tension
○
○
○
○
○
49: Reserved
50: Reserved
Group 3 Analog Input/Output Parameters
CALL NOW 800-985-6929
http://www.automatedpt.com
CALL NOW 800-985-6929
http://www.automatedpt.com
Содержание VFD-VE
Страница 1: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...
Страница 2: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...
Страница 3: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...
Страница 39: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...