Chapter 4 Parameters
|
Revision Dec. 2008, 04VE, SW V2.05
4-139
08-11
08-10
08-12
0Hz
Sleep Function
Frequency command
actual output frequency
sleep time
Wake-up frequency
Sleep frequency
08-13
PID Deviation Level
Unit: 0.1
Control
mode
VF VFPG SVC
FOCPG
Factory Setting: 10.0
Settings 1.0
to
50.0%
08-14
PID Deviation Time
Unit: 0.1
Control
mode
VF VFPG SVC
FOCPG
Factory Setting: 5.0
Settings
0.1 to 300.0 sec
08-15
Filter Time for PID Feedback
Unit: 0.1
Control
mode
VF VFPG SVC
FOCPG
Factory Setting: 5.0
Settings
0.1 to 300.0 sec
08-16
Reserved
08-17
Reserved
08-18
Reserved
08-19
Reserved
08-20
Reserved
08-21
Tension Control Selection
Settings
0 to 4
Factory Setting: 0
Control Mode
Settings
VF
VFPG
SVC
FOCPG TQCPG
0:
Disable
1: Tension closed-loop, speed mode
○
○
○
○
2: Line speed closed-loop, speed mode
○
○
○
○
3:
Reserved
4:
Tension
open-loop,
torque
mode
○
Tension closed-loop, speed mode