Chapter 4 Parameters
|
4-36
Revision Dec. 2008, 04VE, SW V2.05
Pr.
Explanation
Settings
Factory
Setting
VF VFPG SVC FOCPG TQCPG
2: In unwind mode, rewind in reverse direction
08-56
Switch Level for Smart
Start and PID function
0.0~100.0% (according to Pr.08-26)
15.0
○
○
○
○
○
08-57
Frequency for Smart
Start
0.00~600.00Hz 2.00
○
○
○
○
○
08-58
Accel. Time for Smart
Start
0.01~600.00 seconds
3.00
○
○
○
○
08-59
Broken Belt Detection
0: Disable
1: Enable
0
○
○
○
○
08-60
Min. Line Speed of
Broken Belt Detection
0.0~3000.0m/min 0.0
○
○
○
○
08-61
Allowance Error of Line
Speed of Broken Belt
Detection
1.0~6000.0mm 100.0
○
○
○
○
08-62
Detection Time of
Broken Belt
0.00~100.00 sec
1.00
○
○
○
○
08-63
Allowance Error Level
of Tension/Line Speed
PID Feedback
0~100% 100
○
○
○
○
08-64
Allowance Error
Detection Time of
Tension PID Feedback
0.0~10.0 sec
0.5
○
○
○
○
08-65
Error Treatment of
Tension PID Feedback
0: Warn and keep operation
1: Warn and coast to stop
2: Warn and ramp to stop
0
○
○
○
○
08-66
Upper Limit of Tension
PID Feedback
0.0~100.0% 100.0
○
○
○
○
○
08-67
Lower Limit of Tension
PID Feedback
0.0~100.0% 0.0
○
○
○
○
○
08-68
Reserved
08-69
DFM Selection
0: Output frequency
1: Frequency command
0
○
○
○
○
○
08-70
Low-pass Filter Time of
Line Speed
0.00~100.00 sec
0.00
○
○
○
○
○
08-71
|
08-75
Reserved
08-76
Source of Tension
Setting
0: Communication RS-485 (Pr.08-78)
1: Analog input (Pr. 03-00~03-02 is set to 15
tension setting) (Pr.08-78)
0
○
08-77
Max. Tension
0~30000 N
0
○
08-78
Tension Setting
0~30000 N
0
○
08-79
Source of Zero-speed
Tension Setting
0: Disable
1: Communication RS-485 (Pr.08-80)
2: Analog input (Pr. 03-00~03-02 is set to 16 zero-
speed tension) (Pr.08-80)
0
○
08-80
Setting of Zero-speed
Tension
0~30000 N
0
○
08-81
Source of Tension
Taper
0: Communication RS-485 (Pr.08-82)
1: Analog input (Pr. 03-00~03-02 is set to 17
tension taper)(Pr.08-82)
0
○
08-82
Tension Taper
0~100%
0
○
08-83
Friction Compensation 0.0~100.0%
0.0
○
08-84
Compensation
Coefficient of Material
Inertial
0~30000 0
○
08-85
Torque Feed Forward
Gain
0.0~100.0% 50.0
○
08-86
Low Pass Filter Time of
Torque Feed Forward
0.00~100.00 5.00
○
08-87
|
08-99
Reserved
Group 9 Communication Parameters
CALL NOW 800-985-6929
http://www.automatedpt.com
CALL NOW 800-985-6929
http://www.automatedpt.com
Содержание VFD-VE
Страница 1: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...
Страница 2: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...
Страница 3: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...
Страница 39: ...CALL NOW 800 985 6929 http www automatedpt com CALL NOW 800 985 6929 http www automatedpt com ...