115
Disassemble the air filter
②
to be replaced and plug in a new filter;
Restore the filter plastic frame.
Note: In the air condition room, life time of the filter is 1 years.
Fig. 10-3 Diagram of Filter Replacement for control cabinet
2. Check the connection
Follow 10-1 maintenance SOP and turn the system power off.
Take all the safety measures.
Check whether the external power cable and controller are connected well.
3. Dielectric withstanding Test
The procedures are as follows:
Step1: Disconnect the filed input and output cable;
Step2: Short the field input terminals (3 phase) ;
Step3: Short the filed output terminals (3 phase);
Step4: Short transformer auxiliary winding terminals (3 phase), and grounding;
Step5: Short all power cell input terminals and output terminals;
Step6: Disconnect neutral grounding resistor which connected to power cell
U1/V1/W1 if there is a resister, disconnect surge arrestor, input and output voltage
divider from high voltage terminal.
If the input voltage and output voltage rating are not the same, conduct the dielectric
withstand test separately.
Step7: Based on step3, connect the output terminal to ground.
Step8: Measure the insulation resistance between input terminal and ground using
a 1000V megger, the resistance should greater than 100MΩ.
Step9: Apply power frequency high voltage which is listed in the table below at the
input terminal with respect to ground for 60S, no breakdown or flashover occurs.
System voltage
Dielectric withstanding voltage
3.3kV
10kV
6.6kV
19 kV
11kV
27kV
Step10: Measure insulation resistance again. The resistance should greater than
100MΩ, and the variation should less than 30% compared with the data got at first
②
①
Содержание MVF2000 Series
Страница 2: ......
Страница 15: ...11 Standard No Standard Name Used With Adjustable Voltage or Adjustable Frequency Controls or Both...
Страница 36: ...Fig 3 15 date time adjust interface HMI System Click HMI System button to enter into HMI System...
Страница 128: ...Annex B MVF2000 Electrical parameters and dimensions table MVF2000 outline drawings shown below w D H...
Страница 131: ...127 Fig 2 Front view Fig 3 Inside view...