Chapter 4 Parameters
|
Revision July 2008, EG03, SW V1.06
4-7
Group 3 Output Function Parameters
Parameter
Functions
Settings
Factory
Setting
Customer
03-00 Multi-function
Output
Terminal 1
(Relay)
00: disabled
01: Indication during operation
02: Master frequency attained
03: Zero Speed (including shutdown)
04: Over-torque
05: External Fault
06: Low voltage detection
07: Operation Mode indication
08: Fault indication
09: Master Frequency Attained 1
10: Master Frequency Attained 2
11: Over Temperature indication
12: Drive Ready
13: External Emergency Stop (EF1)
14: Software Braking Output
15: OL or OL1 Overload Warning
16: Low Current Indication
17: PID Feedback Error Indication
18: PLC Program Running
19: PLC Program Step Completed
20: PLC Program Completed
21: PLC Operation Paused
01
03-01 Reserved
03-02 Master
Frequency
Attained 1
0.00~160.00 Hz
0.00
03-03 Master
Frequency
Attained 2
0.00~160.00 Hz
0.00
03-04
DC Fan Control
00: Fan runs on power up.
01: Fan begins upon a RUN command. Fan
stops 1 minute after a STOP command.
02: Fan begins upon a RUN command. Fan
stops after a STOP command
03: Fan is controlled by temperature.
Fan will be started at approximate 60°C.
00
03-05 Analog
Output
Signal
1
00
03-06 Analog
Output
Signal
2
00: Output frequency
01: Output current
02: Output voltage
03: Frequency command
04: Power factor loading
01
03-07 Analog Output Gain 1 01~200%
100
03-08 Analog Output Gain 2 01~200%
100
03-09 Analog
Output
2
Selection
00: 0~20mA
01: 4~20mA
01
Содержание AC Motor Drive VFD-G
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 17: ...Chapter 1 Introduction 1 8 Revision July 2008 EG03 SW V1 06 For 150 215HP Frame G Step 1 Step 2 Step 3 Step 4...
Страница 18: ...Chapter 1 Introduction Revision July 2008 EG03 SW V1 06 1 9 For 250 300HP Frame H Step 1 Step 2 Step 3 Step 4...
Страница 23: ...Chapter 1 Introduction 1 14 Revision July 2008 EG03 SW V1 06 This page intentionally left blank...
Страница 45: ...Chapter 2 Installation and Wiring 2 22 Revision July 2008 EG03 SW V1 06 This page intentionally left blank...
Страница 51: ...Chapter 3 Keypad and Start Up 3 6 Revision July 2008 EG03 SW V1 06 This page intentionally left blank...
Страница 141: ...Chapter 4 Parameters 4 90 Revision July 2008 EG03 SW V1 06 This page intentionally left blank...