Chapter 4 Parameters
|
Revision July 2008, EG03, SW V1.06
4-21
Output Signal during Running
Applications Purpose
Functions
Related
Parameters
General application
Provide a signal for
running status
Signal available to stop braking when
the AC motor drive is running. (This
signal will disappear when the AC
motor drive is free-running.)
03-00
Output Signal in Zero Speed
Applications Purpose
Functions
Related
Parameters
General application
Provide a signal for
running status
When the output frequency is lower
than the min. output frequency, a
signal is given for external system or
control wiring.
03-00
Output Signal at Master Frequency
Applications Purpose
Functions
Related
Parameters
General application
Provide a signal for
running status
When the output frequency is at the
master frequency (by frequency
command), a signal is given for
external system or control wiring
(frequency attained).
03-00
Output signal for Over-torque
Applications Purpose
Functions
Related
Parameters
Pumps, fans and
extruders
To protect
machines and to
have continuous/
reliable operation
When over-torque is detected, a
signal is given to prevent machines
from damage.
03-00
06-03
06-04
06-05
Output Signal for Low Voltage
Applications Purpose
Functions
Related
Parameters
General application
Provide a signal for
running status
When low voltage is detected, a signal
is given for external system or control
wiring.
03-00
Output Signal at Desired Frequency
Applications Purpose
Functions
Related
Parameters
General application
Provide a signal for
running status
When the output frequency is at the
desired frequency (by frequency
command), a signal is sent by an
external system or control wiring.
03-00
03-02
03-03
Содержание AC Motor Drive VFD-G
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 17: ...Chapter 1 Introduction 1 8 Revision July 2008 EG03 SW V1 06 For 150 215HP Frame G Step 1 Step 2 Step 3 Step 4...
Страница 18: ...Chapter 1 Introduction Revision July 2008 EG03 SW V1 06 1 9 For 250 300HP Frame H Step 1 Step 2 Step 3 Step 4...
Страница 23: ...Chapter 1 Introduction 1 14 Revision July 2008 EG03 SW V1 06 This page intentionally left blank...
Страница 45: ...Chapter 2 Installation and Wiring 2 22 Revision July 2008 EG03 SW V1 06 This page intentionally left blank...
Страница 51: ...Chapter 3 Keypad and Start Up 3 6 Revision July 2008 EG03 SW V1 06 This page intentionally left blank...
Страница 141: ...Chapter 4 Parameters 4 90 Revision July 2008 EG03 SW V1 06 This page intentionally left blank...