Chapter 4 Parameters
|
Revision July 2008, EG03, SW V1.06
4-41
Group 4: Input Function Parameters
04 - 00
Multi-function Input terminal 1
Factory Setting: 01
04 - 01
Multi-function Input terminal 2
Factory Setting: 02
04 - 02
Multi-function Input terminal 3
Factory Setting: 03
04 - 03
Multi-function Input terminal 4
Settings
00~31
Factory Setting: 04
Setting
Functions
Descriptions
00
Disabled
All unused terminals should be set to 00, to assure they
have no effect on drive operation.
01
Multi-Speed terminal 1
02 Multi-Speed
terminal
2
03 Multi-Speed
terminal
3
04 Multi-Speed
terminal
4
Allows selection of the 15 multi-step speeds. Please refer
to 05-00 to 05-14 to program the 15 step speeds.
05
Reset (NO)
06
Reset (NC)
Clears (Reset) a fault and returns the AC drive to normal
operation.
07
Jog operation (JOG)
Enables the JOG command. Works identical to the JOG
key on the digital keypad.
08
Accel/Decel disable
Stops the acceleration or deceleration of the AC drive. AC
drive then maintains a constant speed.
09
1st and 2nd Accel/Decel
selection
10
3rd and 4th Accel/Decel
selection
A corresponding terminal set to value 09 and closed
selects Accel/Decel time 2. A corresponding terminal set
to value 10 and closed selects Accel/Decel time 3.
Accel/Decel time 4 is selected when both terminals are
closed.
11
B.B. (NO) input
12
B.B. (NC) input
Enables the base block (pause) function.
Please refer to Pr.08-08, for base block functions.
13 Increase
Frequency
14 Decrease
Frequency
Enables the external terminals to increase or decrease the
Master Frequency command each time an input is
received. Terminals are not active during a stop
command.
15
Emergency stop (NO)
16
Emergency stop (NC)
Generates an external fault (EF1). The function is identical
to the external terminal (EF).
17 KEYPAD(open),
EXT(close)
External selection of the Operation Command Source.
(Keypad = terminal open) or (External terminals = terminal
closed). This setting is valid when Pr.02-01 is set to 00.
Otherwise, the Operation Command Source will follow the
setting in Pr.02-01.
Содержание AC Motor Drive VFD-G
Страница 1: ......
Страница 2: ......
Страница 3: ......
Страница 17: ...Chapter 1 Introduction 1 8 Revision July 2008 EG03 SW V1 06 For 150 215HP Frame G Step 1 Step 2 Step 3 Step 4...
Страница 18: ...Chapter 1 Introduction Revision July 2008 EG03 SW V1 06 1 9 For 250 300HP Frame H Step 1 Step 2 Step 3 Step 4...
Страница 23: ...Chapter 1 Introduction 1 14 Revision July 2008 EG03 SW V1 06 This page intentionally left blank...
Страница 45: ...Chapter 2 Installation and Wiring 2 22 Revision July 2008 EG03 SW V1 06 This page intentionally left blank...
Страница 51: ...Chapter 3 Keypad and Start Up 3 6 Revision July 2008 EG03 SW V1 06 This page intentionally left blank...
Страница 141: ...Chapter 4 Parameters 4 90 Revision July 2008 EG03 SW V1 06 This page intentionally left blank...